Beta 599DGT-A/10 Mode D'emploi page 20

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
ANGLE READOUT MODE OPERATON
Angle mode
Blinking
Current angle
80% of set value reached
Current angle
Note:
1. When the angle measurement is set, the unit of measurement will become ° (Deg.) .
2. Hold the torque wrench fast, in the horizontal position, when the "angle mode" is entered.
3. After a few seconds the "angle mode" will start, and
4. When the wrench is released, in the "angle mode", the display will show the corresponding torque
value with blinking LEDs.
5. When 80% of the set value is reached, the green LEDs will start blinking and an intermittent sound
will be heard.
6. When 99.5% of the set value is reached, a continuous sound will be heard, and the green LEDs
will stop blinking and will remain on together with the red LEDs.
20
*Note 1
Press
*Note 2
*Note 3
Apply force and turn
wrench
Release
Over 80% of set value
((...((...
*Note 5
Set value reached
Release
((...((...
...)) ...))
Current torque
* Nota 4
...)) ...))
Current torque
*Note 6
will blink.

Publicité

Table des Matières
loading

Table des Matières