Wiring diagram LM OG-TAE(R) 2 x 100 / Changing the battery

6. Wiring diagram LM OG-TAE(R) 2 x 100

LM OG-TAE(R) 2 x 100
Art. n° 102128, 102130, 102131, 103132
The wiring configuration is different for the meters 102128 and 102130 to: channel 1 =
white; channel 2 = green
Wiring diagram
R 1K2
R
1K2
OG-TAER 200
LM OG-T 100 / LM OG-HFT 1" / LM OG-HFT
66,75 PPL Art. n° 102101 / 102920 / 102915
Wiring diagram
Reedswitch
white

7. Changing the battery

If you change the battery, please proceed as follows:
Picture 1: Loosen
the battery cover
Battery: Lithium CR123A
AUSG.1
OUT 1
AUSG.2
OUT 2
GND
0V
SUPPLY
6-24 VDC
brown
Picture 2: Take out
the battery
LM_OG_BA_98_1105
LM OG-T 2 x 100
Art. n° 102106
Wiring diagram
yellow
white
Picture 3: Insert the new
battery and press the reset
button to check the function
of the register
Page 13/28
GRÜN
GREEN
WEISS
WHITE
BRAUN
BROWN
GELB
YELLOW
Reedswitch
green
brown
Picture 4: Insert the
battery cover, then screw
the battery