Indoor Unit Installation
3-3. Wall embedded piping
Follow the instructions given under left-back piping.
1) Insert the drain hose to this depth so it won't be pulled
out of the drain pipe.
3-4. Bottom or left side piping
1) Cut off the pipe port cover with a copping saw.
• For bottom piping: On the bottom of the front grille
• For left side piping: On the side cover (front grille side and unit side)
Apply the blade of the copping saw to the notch, and cut off the pipe port cover along the uneven inner surface.
The figure shows the case of left-bottom piping.
2) After cutting off the pipe port cover, perform filing.
Remove the burrs along the cut section using a half round needle file.
3) Wrap the refrigerant pipes and drain hose together with
Then, insert the drain hose and refrigerant pipes into the wall hole after inserting them into the cut out piping hole
opened.
NOTE
• Be careful not to let chips enter the driving section of the arm.
• Be careful not to put pressure on the lower front panel.
7
Front grille side
Insert the drain
hose to this depth
so it won't be pulled
1-15/16"
out of the drain pipe.
(50mm)
or more
Outer wall
φ1-3/16" (30mm) or more
Side cover (unit side)
Side cover
(front grille side)
K
insulation tape.
Right bottom piping
Inner wall
Drain hose
Vinyl chloride
drain pipe (VP-30)
Bind refrigerant pipe and drain hose
together with adhesive vinyl tape.
Left side
piping
Left bottom piping