Scope Of Use; Technical Data; Points To Note When Setting Up The Compressor; Setting The Pressure Switch - Bavaria BAC 200/20 OF Mode D'emploi D'origine

Table des Matières

Publicité

Anleitung_BAC_200_20_OF_SPK1__ 22.05.13 15:13 Seite 13

3. Scope of use

The compressor is designed for generating
compressed air for tools operated by compressed
air.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.

4. Technical data

Power supply:
230 ~ 50 Hz
Motor rating in kW:
Operating mode:
S3 - 40% - 10 min
Compressor speed in rpm:
Operating pressure in bar:
Pressure vessel volume in litre:
Theoretical intake rate in l/min.:
Sound power level L
in dB:
WA
K WA uncertainty
Protection type:
Machine weight in kg:
Operating mode S3 - 40% - 10min: S3 = Intermittent
mode without influencing the starting process. This
means that during a period of 10 min the max.
operating time is 40% (4 min).
5. Points to note when setting up the
compressor
Examine the machine for signs of transit
n
damage. Report any damage immediately to the
company which delivered the compressor.
The compressor should be set up near the
n
working consumer.
Avoid long air lines and long supply lines
n
(extensions).
Make sure the intake air is dry and dust-free.
n
Do not set up the compressor in damp or wet
n
rooms.
The compressor may only be used in suitable
n
rooms (with good ventilation and an ambient
temperature from +5°C to +40°C). There must be
no dust, acids, vapors, explosive gases or
inflammable gases in the room.
The compressor is designed to be used in dry
n
rooms. It is prohibited to use the compressor in
areas where work is conducted with sprayed
water.
Operate the equipment only on a firm, level
n
surface.
6. Assembly and starting
Important!
You must fully assemble the appliance before
using it for the first time.
After use, always switch off the equipment
immediately and pull out the power plug.
6.1 Fitting the wheels (3)
0.9
Fit the supplied wheels as shown in Fig. 4.
6.2 Fitting the supporting foot (4)
2700
Fit the supplied rubber stopper as shown in Fig. 5.
8
20
6.3 Voltage
Before you use the machine, make sure that the
140
mains voltage complies with the specifications on the
96
rating plate. Long supply cables, extensions, cable
3 dB
reels etc. cause a drop in voltage and can impede
motor start-up. In the case of low temperatures
IP 20
below +5°C, motor start-up is jeopardized as a result
17
of stiffness.
6.4 On/Off switch (8)
To switch on the compressor, pull out the knob (8).
To switch off the compressor, press the knob (8) in
again. (Fig. 2)
6.5 Adjusting the pressure: (Fig. 1)
You can adjust the pressure on the pressure
n
gauge (6) using the pressure regulator (7).
The set pressure can be taken from the quick-
n
lock coupling (5).

6.6 Setting the pressure switch

The pressure switch is set at the factory.
Switch-on pressure 6 bar
Switch-off pressure 8 bar
GB
13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

40.073.40

Table des Matières