NOTE: The top of the sensor should be between four and
six inches above the floor.
NOTE: The receiving sensor has a green LED. Ensure that
the lens on this sensor is not exposed to direct sunlight.
 Mark the position of the hole in the bracket.
 Secure brackets in place using nails or drill 3/16 in. pilot
holes and secure with lag screws. Tighten screws with
an 7/16 in. socket.
NOTE: Use lag screws and concrete anchors (not
included) when installing the brackets into concrete, brick,
or other masonry.
WARNING:
To avoid the risk of death, electric shock, or serious
personal injury ensure that the garage door opener is
unplugged before wiring the sensors.
Safety Sensor
(Receiver)
Arrow
LED
(Green)
Safety
Screw
Sensor
INSTALLATION
Safety Sensor
(Transmitter)
LED
(Red)
Lag
WARNING:
Connect the sensors using low voltage wires provided
only Using other wires may cause signal interference or
malfunction and can result in electric shock or serious
personal injury.
 Route the wires from the sensors to the door sensor wire
terminals. Attach the wires to the wall and ceiling using
the insulated staples. Secure the staples to the wall and
ceiling using a hammer.
 Using wire strippers, strip 1/2 in. of insulation from the
ends of each wire.
 To install or remove wires from a wire terminal, depress
the tab beside the terminal.
Fig. 52
Insulated
Staples
Fig. 53
30 - English
Safety
Sensor
Safety Sensor
Fig. 54
Power
Head
Wires
Fig. 55