Lighting
transformer
secondary
circuit
12V 
LED spotlight
power cables
Cable section
To avoid voltage drop, the receiver must be installed near to the lighting transformer (TBTS 12V) and a cable of section
2.5mm should be used.
The transformer used must have a power (expressed in VA) at least equal to the sum of the power consumed by the
spotlights connected to it.
If the transformer supplies several spotlights, each spotlight should be supplied via a cable adapted to its power.
Standard NF C15-100 limits the permissible voltage drop to 5%, or 0.6V in the case of the TBTS 12V.
In order to ensure the installation is compliant, and to avoid energy wastage and malfunctioning spotlights, the use of cables
with a sufficient section according to the length required is recommended. The table below will help you find the maximum
permissible distance according to the section of the cable.
Max. consumed
Model
15 W LED
30 W LED
Page 5 of 7
2 1
3
power
2.5mm²
15 W
26.4 m
34W
12.0m
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Remote control receiver
1
2
3 x 2.5 mm² cables
going to the remote
control receiver
3
1: Black
2: Brown
3: Grey
Cable section
4mm²
42.2 m
19.2m
Maximum length of the cable
Lights
2 1
3
6mm²
63.3 m
28.8m
10mm²
48.0 m
Rev. D