Ariston A5GG1F EX Mode D'emploi page 7

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Unscrew the nozzle using a
special nozzle socket spanner
(see fi gure) or with a 7 mm
socket spanner, and replace it
with a new nozzle that is suited to the new type of gas
(see Burner and nozzle specifi cations table).
Adjusting the gas oven burner's minimum setting:
1. Light the burner (see Start-up and Use).
2. Turn the knob to the minimum position (MIN)
after it has been in the maximum position (MAX) for
approximately 10 minutes.
3. Remove the knob.
4. Tighten or loosen the adjustment screws on the
outside of the thermostat pin (see fi gure) until the flame
is small but steady.
! If the appliance is connected to liquid gas, the
adjustment screw must be fastened as tightly as
possible.
5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not extinguished.
Table of burner and nozzle specifications
Table 1
Burner
Diameter
(mm)
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
51
(Small)(A)
Oven
-
Grill
-
Nominal (mbar)
Supply
Minimum (mbar)
Pressures
Maximum (mbar)
Thermal power
By-Pass
kW (p.c.s.*)
1/100
Nominal
Reduced
(mm)
3,00
0,7
41
1,90
0,4
30
1,00
0,4
30
2.80
1.0
46
2,30
-
-
Adapting the grill
V
I
spanner, and replace it with a new nozzle that is
suited to the new type of gas (see Burner and nozzle
specifi cations table).
! Be careful of the spark plug wires and the
thermocouple tubes.
! The oven and grill burners do not require primary air
adjustment.
! After adjusting the appliance so it may be used with
a different type of gas, replace the old rating label with
a new one that corresponds to the new type of gas
(these labels are available from Authorised Technical
Assistance Centres).
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet hose in
accordance with current national regulations relating to
"regulators for channelled gas".
Gaz liquide
Gaz naturel
Nozzle
Flow*
Nozzle
1/100
g/h
1/100
(mm)
***
**
(mm)
87
218
214
128
69
138
136
104
50
73
71
78
80
204
200
119
75
167
164
114
28-30
37
20
25
35
45
Replacing the grill burner
nozzle:
1. Remove the oven burner
after loosening screw V (see
fi gure).
2. Unscrew the grill burner
nozzle using a special nozzle
socket spanner (see fi gure) or
preferably with a 7 mm socket
Flow*
l/h
S S
A
R
286
181
A5GG1F EX
A5GG1F EX
A5GG1F EX
95
A5GG1F.B EX
A5GG1F.B EX
A5GG1F.B EX
267
219
20
17
25
GB
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

A5gg1f.b ex

Table des Matières