Before First Use - Hamilton Beach Commercial HVC406 Manuel D'utilisation

Scelleuse sous vide à chambre
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Setup
Space Requirements
Unit must be set on flat and level surface with about 5"–7" of clearance for side vents.

Before First Use

NOTE: This unit was shipped without oil. See "How to Add Oil" for instructions. Do not operate without
oil or with low oil since this will damage the pump.
How to Add Oil
1. Unplug from outlet and from cord inlet.
2. Use wrench to remove the oil fill cap on right side of unit.
3. Fill with only Lubriplate L0944 "Light" vacuum pump oil.
4. Make sure oil level is between MIN and MAX in oil indicator.
5. Make sure complete and intact seal ring is fitted within the oil fill cap,
and replace as needed.
6. Use the wrench to turn the oil fill cap and close.
7. Wait a few minutes.
8. Check whether the oil level is between MIN and MAX of oil level sight glass.
Fill with more oil if lower than MIN.
9. If the oil level is between MIN and MAX of oil level sight glass.
10. Check the oil level every week and fill as needed.
Special Oil for Vacuum Pump
Use only Lubriplate L0944 "Light" vacuum pump oil.
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Xv05

Table des Matières