Inspect vacuum sealer and its various parts and replace as follows:
Weekly
Check oil by looking at the oil indicator.
Check seal pad under lid for wear.
Check lid gasket and lid.
Check seal bar for wear.
Every 6 Months
Replace oil in vacuum pump. Contact Technical Services.
Replace seal pad under lid.
Replace lid gasket.
Replace sealing tape and sealing wires.
Yearly
Check oil exhaust filter. Contact Technical Services.
Cleaning
w WARNING
Electrical Shock Hazard. Before cleaning the Vacuum Sealer, make sure the Vacuum Sealer is
OFF (O) and the plug is removed from the outlet/power source.
w CAUTION
Burn Hazard. The Seal Bar and Vacuum Chamber Seal get hot and can cause burns. Avoid
contact. Allow Vacuum Sealer to cool for 20 minutes before cleaning.
Inspect the vacuum sealer and its various parts and clean as follows:
Run the Preheating Program
Run the Preheating Program daily. See page 6.
Clean Inside and Outside
Unplug unit.
Let unit cool completely before cleaning.
Wipe vacuum chamber, lid, sealing bar, silicone holder, and exterior with a clean, moist cloth.
Do not use abrasive materials, scratching cleansers, or scouring pads to clean since these may damage
the finish or spoil the clarity of the lid.
Wipe off all mild soap and chemical cleansers since residue may corrode the finish.
Tips
Vacuum Confirmation
To check quality of vacuum, check tightness of the pouch and its contents. Check for air leaks and
pockets. If you find that contents are not tightly vacuumed, increase the vacuum time by
5 seconds and run the vacuum again.
Seal Confirmation
To check quality of the seal, check seal of pouch. A complete seal will appear clear while an incomplete
seal will appear bubbly. If the seal is incomplete, increase seal time by 0.1 second. If the seal appears
white, decrease seal time by 0.1 second. After determining the appropriate time adjustments, vacuum
and seal again.