Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
controls (Fig.3). Make 4, Ø8 holes in the ceiling and drive in 3
screws without completely tightening them. Pay attention not
to insert the screw into the hole marked with an X on the hole
template (the screws and expansion plugs must be suitable
for the type of wall).
- Take the upper part of the structure B (Fig.4) and insert the
3 slots onto the 3 screws that are not completely tightened.
Rotate slightly to fit (Fig.4). Drive in the fourth screw X and
tighten the remaining 3 to allow definitive blocking of the
upper part of structure B.
- Take the lower part of the telescopic structure C and insert it
into the upper structure B (Fig.5). Adjust the height by refer-
ring to the amounts X indicated in Fig.14 and block it using
the 8 screws G that are supplied (Fig.6).
• Suction version: Fix the flexible pipe to the prepared air
evacuation hole (Fig.7).
• Filtering version: Connect the air exhaust pipe to the re-
circulation air deflector M, and tighten the screw I, as shown
in Fig.8. The carbon filters must be fitted inside the suction
hood as shown in Fig.16. There are two different types of
active carbon filters: long-lasting regenerable active carbon
filters (washable) (Fig.17) and standard non-regenerable ac-
tive carbon filters (Fig.16).
- Take the upper chimney piece and fix it to the structure using
the 2 screws A (Fig.9). Join the lower chimney piece with the
upper one and fix it carefully using adhesive tape L (Fig.10A).
- Unscrew the 2 screws O, max 3 mm (Fig.10A). Insert the
suction unit inside the structure paying attention that the
previously unscrewed screws O, hook into the slots in the
lower part as indicated in (Fig.10B). Drive in the 3 screws N
(supplied) and tighten the 2 screws O (Fig.10B).
- Fix the air evacuation pipe H (not supplied) onto the connec-
tion flange F (Fig.11).
- Remove adhesive tape L and rest the lower chimney piece
above the cooker hood (Fig.12).
- If necessary, fix the lower duct to the hood from the inside,
using the screws P (Fig.13).

USE AND MAINTENANCE

• We recommend that the cooker hood is switched on before
any food is cooked. We also recommend that the appliance is
left running for 15 minutes after the food is cooked, in order
to thoroughly eliminate all contaminated air.
The effective performance of the cooker hood depends on
constant maintenance; the anti-grease filter and the active
carbon filter both require special attention.
• The anti-grease filter is responsible retaining the grease
particles suspended in the air, therefore it is subject to clog-
ging with variable frequency according to the use of the
appliance.
- To prevent the danger of possible fires, at least every 2
months one must wash the anti-grease filters by hand using
non-abrasive neutral liquid detergents or in the dishwasher
at low temperatures and on short cycles.
- After a few washes, colour alterations may occur. This does
not give the right to claim their replacement.
• The active carbon filters are used to purify the air that is
sent back into the room and its function s to mitigate the
unpleasant odours produced by cooking.
- The non-regenerable active carbon filters must be replaced
at least every 4 months. The saturation of the active charcoal
depends on the more or less prolonged use of the appliance,
on the type of kitchen and on the frequency with which anti-
grease filter is cleaned.
- Regenerable active charcoal filters must be washed by hand,
with non abrasive neutral detergents, or in the dishwasher at
a maximum temperature of 65°C (the washing cycle must be
complete without dishware). Remove excess water without
damaging the filter, remove the plastic parts, and let the mat
dry in the oven for at least 15 minutes approximately at a
maximum temperature of 100°C. To keep the regenerable
charcoal filter functioning efficient this operation must be
repeated every 2 months. These must be replaced at least
every 3 years or when the mat is damaged.
• Before remounting the anti-grease filters and the regen-
erable active charcoal filters it is important that they are
completely dry.
• Clean the hood frequently, both internally and externally,
using a cloth dampened with denatured alcohol or neutral
liquid detergents that are non abrasive.
• The lighting .system is designed for use during cooking
and not for the prolonged general lighting of the room. The
prolonged use of the lighting system significantly decreases
the average duration of the bulbs.
• Attention: The non compliance with the hood cleaning
warnings and with the replacement and cleaning of the filters
entails risk of fires. One therefore recommends keeping to the
suggested instructions.
• Replacing halogen light bulbs (Fig.18):
To replace the halogen light bulbs B, remove the glass pane
C using a lever action on the relevant cracks.
Replace the bulbs with new ones of the same type.
Caution: Do not touch the light bulb with bare hands.
• Commands (Fig.19):
The key symbols are explained below:
A = LIGHT
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III
F = AUTOMATIC STOP TIMER - 15 minutes (*)
• If your appliance does not have the INTENSIVE speed func-
tion, press key E for two seconds and it will be activated for 10
minutes after which it will return to the previously set speed.
When the function is active the LED flashes. To interrupt it
before the 10 minutes have expired press key E again.
• Clean Air:
By pressing key F for two seconds (with the hood switched off)
the "clean air" function is activated. This function switches
the appliance on for ten minutes every hour at the first speed.
As soon as this function is activated the motor starts up at the
first speed for ten minutes. During this time key F and key
C must flash at the same time. After ten minutes the motor
switches off and the LED of key F remains switched on with
a fixed light until the motor starts up again at the first speed
after fifty minutes and keys F and C start to flash again for ten
minutes and so on. By pressing any key for the exclusion of
the hood light the hood will return immediately to its normal
functioning (e.g. if key D is pressed the "clean air" function is
deactivated and the motor moves to the 2nd speed straight
away. By pressing key B the function is deactivated).
(*) The "AUTOMATIC STOP TIMER" delays stopping of the
hood, which will continue functioning for 15 minutes at the
- 19 -

Publicité

Table des Matières
loading

Table des Matières