Weight
Dimensions (mm) LxWxH
Rated electrical values
Inlet pressure
MIG/MAG flow rate (at 20 °C)
TIG flow rate (at 20 °C)
Tab. 2
General information
3.2 Abbreviations
BAL.0253.0 • 2017-04-07
EWR
Approx. 1.3 kg
118 × 148 × 58 mm
24 VDC, 450 mA–750 mA
2.5–5 bar
5–22 l/min
22–30 l/min ±2 l/min
2–13 l/min
13–19 l/min
NOTICE
• The inlet pressure must not exceed 6 bar.
• The EWR does not work correctly at inlet pressures < 2 bar.
The outlet stagnation pressure can be set in increments of 0.2 bar within the
range 0.2 to 2.0 bar.
The maximum outlet stagnation pressure corresponds to the inlet pressure
minus 1.5 bar.
Shunt
150 ampere
300 ampere
500 ampere
Tab. 3
Working ranges
 14.1 Shunt types on page EN-16
EWR
MIG
MAG
TIG
A
Tab. 4
Abbreviations
3 Product description
±1 l/min
10.6–46.2 cfh ±2.1 cfh
46.2–63.0 cfh ±4.2 cfh
±1 l/min
4.2–27.3 cfh
±2 l/min
27.3–63.0 cfh
Working range
45–150 ampere
90–300 ampere
150–500 ampere
Electronic welding regulator
Metal inert gas
Metal active gas
Tungsten inert gas
Ampere
±2.1 cfh
±4.2 cfh