• Maximum effective internal inductance (Li) and capacitance (Ci):
Type
IM08-01B-N-ZWO
IM12-02B-N-ZWO
IM12-04N-N-ZWO
IM18-05B-N-ZWO
IM18-08N-N-ZWO
IM30-10B-N-ZWO
IM30-15N-N-ZWO
The values apply to potted cables which are 2 m long.
Installation remarks / Mounting
• Adhere to the respective national regulations and provisions.
• Avoid electrostatic charging on plastic units and cables.
• Protect unit and cable against destruction.
• The unit is not suitable for installation in walls which separate zone 0 from zone 1.
• The relevant installation regulations must be adhered to.
• Metal housing parts must be connected to potential by suitable mounting.

Maintenance / Repair

The unit must not be modified nor can it be repaired. In case of a fault please contact the
manufacturer.
If needed, you can obtain the data sheet or the type test certificate from the manufacturer
(see cover sheet).
Internal inductance total
(μH)
70
340
130
45
50
140
110
Internal capacitance total
(nF)
80
140
140
145
155
145