How To Use Guide - WOLFF VI-D4 Traduction Du Mode D'emploi Original

Masquer les pouces Voir aussi pour VI-D4:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.

How to use guide:

Picture below illustrates meter's front and back panel with most important elements marked:
• To turn on the meter press ON/HOLD button.
• To set the scale press SET button. There are 7 available scales:
1)
Concrete
2)
Cement Screed
3)
CM Cement Screed
4)
Anhydrite Screed
5)
Anhydrite Screed
6)
15.3 Scale
7)
Relative Scale (0-100%)
Name of chosen scale will appear in the scale indicator field.
To see detailed description of each scale go to Available scales section.
• To set the mode of measurement press ON/HOLD button. There are 2 available modes:
1. Normal
2. Max. Hold
The display color will change depending on which mode was chosen.
To see detailed description of each mode go to Modes & functions section.
• To make a measurement press the meter against the tested surface until all spring electrodes are
completely blocked.
!
Caution: Do not press the device too intensely as this may harm the electrodes.
!
Caution: Fingers SHOULD NOT touch the sensor plate and electrodes while measuring.
The meter should be held in the middle while measuring
( see picture below ).
It is recommended to repeat the measurement in
a few points situated next to each other as humidity
has a tendency of uneven distribution. If the measurements
vary, only the highest outcomes should be used.
To switch off the meter press ON/HOLD button for
around 2 seconds.
WOLFF GmbH & Co. KG | D-74360 Ilsfeld | Ungerhalde 1 | Tel. +49 (0)7062-91556-0 | Fax +49 (0)7062-91556-10 | E-Mail
(0-6%H
O)
2
(0-6%H
O)
2
(0-4% CM)
(0-3.5% H
O)
2
(0-1.9% CM)
(0.3-15.3m)
info@wolff-tools.com | Internet www.wolff-tools.de
8