Impeller Replacement - Flotec FPSC2200A-10 Notice D'utilisation

Masquer les pouces Voir aussi pour FPSC2200A-10:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Impeller Replacement

First: Turn off power to the pump, disconnect the dis-
charge piping, and lift the pump out of the sump BY
THE HANDLE ON TOP OF THE MOTOR (not by the
cord).
Step 1: Remove the three screws holding the motor to
the base and lift the motor off the base.
Step 2: Hold the motor shaft with a screwdriver and
unscrew the impeller as shown.
NOTE: The impeller has a left-hand thread, so it loosens
to the right (
).
For parts or assistance, call Flotec Customer Service at
4831 0205
Step 3: Thread the new impeller onto the motor shaft as
shown (left-hand thread – tightens to the left
Step 4: Re-mount the motor on the base. Be sure to
mount it so that the switch is clear of the discharge and
all other obstructions in the sump.
Last: Run the pump through one complete cycle after it
is assembled and reinstalled. It should operate correctly
and you should not hear any sounds of scraping or
dragging from the pump.
1-800-365-6832
8
4832 0205
).

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fpsc2250a-10Fpsc3200a-10Fpsc3250a-10Fpsc4550a-10

Table des Matières