How to use the Temperature Control Knob
Safety Stop
Override
Additional Safety Measure:
After installing the shower panel, it is recommended that a test be performed to ensure
the actual water temperature (hot position) is consistent with the temperature setting on
the panel's thermostatic valve control.
Performing the temperature control knob accuracy check
• Turn on the water and direct to the handshower
• Turn the temperature control knob to the 12
O-Clock position.
• Using a temperature test meter or similar
testing device (not included), check to make
sure the temperature recorded for the
handshower water output does not exceed
100.4 F.
Please adjust temperature according to the following steps below:
Attention:
• The maximum water temperature output should be
100.4 F.
• If the user wishes to re-set the maximum water
temperature default value, please call
1-888-919-6492.
How to use the Temperature Control Knob:
• Turning the handle clockwise makes the water
cooler;turning the handle counter-clockwise makes
the water warmer.
• When the safety stop override is at the 12:00
position,the output water is 100.4°F , the handle
will stop.
• If a user wants water hotter than 100.4°F, press
the safety stop override button and continue
turning the handle counter-clockwise.