ECOFOREST ecoGEO Basic Manuel D'utilisateur page 52

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ecoGEO B/C 5-22
Specification
Place of installation
Type of brine system
Heating
Application
HTR - High temperature recovery system
Integrated active cooling
Passive outdoor cooling control
Compressor range of modulation
Heating power
2
COP
, B0W35
Active cooling power
Performance
2
EER
, B35W7
Maximum unassisted DHW temperature
Maximum assisted DHW temperature
Noise emission level
Heating outlet temperature
Cooling outlet temperature
Brine inlet temperature
Operation
Cooling circuit pressure
limits
Production / Pre-load circuit pressure
Brine / Pre-load circuit pressure
Maximum DHW storage tank pressure
Refrigerant type / load
Working
Compressor oil type / load
fluids
Antifreeze agent recommended for brine circuit
1/N/PE 230 V / 50 Hz
Maximum recommended external protection
Electrical
Maximum consumption
data:
Maximum consumption
Single phase
Starting current
Correction of cosine φ
3/N/PE 230 V / 50 Hz
Maximum recommended external protection
Electrical
Maximum consumption
data:
Maximum consumption
Three phase
Starting current
Correction of cosine φ
Height x width x depth
Dimensions
and weight
Empty weight (without assembly)
Replacing or combining the geothermal collector with one or more ecoGEO AU12 aerothermal units. Refer to the ecoGEO AU12 aerothermal units
1.
manual for more detailed information.
In compliance with EN 14511, this includes the consumption of the circulation pumps and the compressor driver.
2.
Considering brine and production flows of 2500 l/h.
3.
Considering a heat ramp of 20ºC to 50ºC in absence of consumption.
4.
Considering support provided by the emergency electrical resistor or the HTR system. Maximum DHW temperature with the HTR system can be
5.
limited by the compressor discharge temperature.
In compliance with EN 12102, this includes the acoustic insulation kit of the compressor.
6.
Always consult regional regulations before using the antifreeze agent.
7.
The admissible voltage range for proper operation of the heat pump is ±10%.
8.
Maximum consumption can vary significantly according to working conditions, or if the compressor's range of operation is restricted. Refer to the
9.
technical service manual for more detailed information.
1
2
, B0W35
2
, B35W7
5
6
8
9
2
, B0W35
2
, B0W55
8
9
2
, B0W35
2
, B0W55
ecoGEO
Units
B/C1
-
-
Geothermal / Aerothermic / Hybrid
-
-
-
--
-
--
%
kW
-
kW
--
-
--
ºC
ºC
db
ºC
ºC
ºC
bar
bar
bar
bar
kg
R410A / 1,70
kg
7
-
-
A
kW/A
kW/A
A
-
-
A
kW/A
kW/A
A
-
ecoGEO B: 1060x600x710
mm
ecoGEO C: 1804x600x710
B: 185
Kg
C: 247
52
User manual ecoGEO
ecoGEO
ecoGEO
ecoGEO
B/C2
B/C3
B/C4
Indoors
--
25 to 100
6 to 25,9
4,9
7 to 29
5
58
70
35 to 46
20 to 60
4 to 35
-10 to +35
2 to 45
0,5 to 3 / 1,5
0,5 to 3 / 0,7
8 (Only for ecoGEO C)
R410A / 2,00
POE/1,18
Propylene glycol
C40A
5,8/25,2
8,5/36,8
11,1
0,96-1
C16A
5,8/8,4
8,5/12,2
3,7
0,96-1
B: 193
B: 185
B: 193
C: 255
C: 247
C: 255