Impianto Elettrico; Elektroanlage - Space SDE2250LIKA Traduction Des Instructions Originales

Table des Matières

Publicité

11.

IMPIANTO ELETTRICO

Installazione da eseguire dall'utilizzatore
11. ELECTRICAL INSTALLATION
Power installations must be made by the user

11. ELEKTROANLAGE

Netzanschluss nur durch Elektrofachkräfte
1
V
0
HZ
50/60
FU
50/60
FU
L1
L2
L3
PE
nero 4mmq vers.400V
nero 6mmq vers.230V
L1
L2
1
13
15
9
11
5
0
IG
2
16
10
14
12
6
23
24
FU1
nero 1.5mmq
17
18
19
FU2
17
18
19
nero 2.5mmq
KM1
KM2
V1
W1
U1
U2
M1
3
MORSETTO
TR
TRASFORMATORE 100VA 0-230-400/0-24/0-18
STM1/2 TERMOSONDA MOTORE COLONNA 1/2
SCA
SCHEDA CONTROLLO ALLINEAMENTO
SA
SEGNALATORE ACUSTICO CARRELLI AD ALTEZZA PERICOLOSA
RC
ANTIDISTURBO BOBINA CONTATTORI
R
RESISTENZA 1.21k 1/2W
M1/2
MOTORE COLONNE1/2
KS
RELE' COMANDO SALITA
KM1/2
CONTATTORE COMANDO MOTORE 1/2
IG
INTERRUTORE GENERALE CON INVERSIONE DI MARCIA E COMANDO
FUSIBILE PROTEZIONE SECONDARIO TR.18Vac 5x20F 2A 250V
FU4
RAPIDO
FUSIBILE PROTEZIONE SECONDARIO TR.24Vac 5x20F 4A 250V
FU3
RAPIDO
FUSIBILI PROTEZIONE PRIMARIO TR:
FU2
- VERS.230V 5x20F 1A 250V (RAPIDO) VERS.400V 10.3x38 1A 500V gl
(RAPIDO)
TERNA FUSIBILI PROTEZIONE LINEA MOTORI:
FU1
- 230V 10.3x38 32A 400V Am (2x2.6KW) 14x51 40A 500V aM (2x3.5KW)
- 400V 10.3x38 20A 500V Am (2x2.6KW) 10.3x38 25A 500V aM (2x3.5KW)
FC2/4
FINECORSA DISCESA COLONNE 1/2
FCP1/2 INTERRUTTORE DI PROSSIMITA` COLONNE 1/2
D
DIODO
CN1
CONNETTORE 14 POLI
C
CONDENSATORE ELETTROLITICO 0.47 microF 50V
RIFER. NOMENCLATURA
230
400
MOT.
32A aM
20A aM
2x2.6KW
40A aM
25A aM
2x3.5KW
400
0
16
18
230
FU4
24
FU3
0
0
L3
9
15
TR
STM2
25
giallo/verde 1mmq
STM1
16
15
KS
V2
W2
9
rosso 1mmq
M2
3
11. INSTALLATION ELECTRIQUE
L'installation doit être prise en charge par l'utilisateur
11. ESQUEMA ELECTRICO
La instalación tiene que efectuarla el utilizador
marrone 1mmq
CN1
2
1
blu 1mmq
rosso 1mmq
20
14
13
12
11
12
21
8
12
1
11
IG
11
2
KS
7
FCP1
FCP2
22
22
22
22
22
R
D
D
+
-
KS
FC2
FC4
D
D
3
5
3
5
10
TERMINAL
TRANSFORMER 100VA 0-230-400/0-24/0-18
MOTOR THERMAL PROTECTION 1/2
ALIGNMENT CONTROL BOARD
DANGEROUS HEIGHT SIREN
CONTACTOR COLL FILTER
RESISTANCE
MOTOR COLUMN 1/2
UP SWITCH RELAY
1/2 MOTOR CONTROL CONTACTOR
MAIN SWITCH WITH REVERSE AND CONTROL
TR SECONDARY SAFETY FUSE 18Vac 5x20F 2A 250V RAPID
TR SECONDARY SAFETY FUSE 24Vac 5x20F 4A 250V RAPID
TR PRIMARY PROTECTIVE FUSES:
- VERS.230V 5x20F 1A 250V (QUICK-TYPE) VERS.400V 10.3x38 1A
500V gl (QUICK-TYPE)
TRIAD OF MOTOR LINE PROTECTION FUSES:
- 230V 10.3x38 32A 400V Am (2x2.6KW) 14x51 40A 500V aM (2x3.5KW)
- 400V 10.3x38 20A 500V Am (2x2.6KW) 10.3x38 25A 500V aM (2x3.5KW)
LOWER LIMIT SWITCH COLUMN 1/2
PROXIMITY SWITCH COLUMN 1/2
DIODE
14-POLE CONNECTOR
ELECTROLYTIC CONDENSER 0.47 microF 50V
NOMENCLATURE
0471-M001-5-P1
1-2 alimentazione 18Vac
9 0V 24VAC
11 0V 24VDC
12 24V 24VDC
14 13 12 11 10 9
8
7
6
5
14
13
12
11
10
9
5
8
7
6
7
7
3
IG
4
12
rosso 1mmq
46
+
C
-
6
SA
47
blu 1mmq
RC
KM2
9
9
9
11
SCA
4
3
2
1
1
2
3
4
4
KM1
RC
9
9
5
3
49

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sde2250likt

Table des Matières