Input circuit monitor
Pick-up level:
Signalling modes
Output signals
A1 and A12:
Frontplate signals:
Output contact AF:
Table 2: Type of output contact
Material
Symbol
Gold flashed
silver alloy
Relay approved by UL, CSA, TÜV, SEV
Direction of action:
Accuracy data (acc. to DIN/IEC 770)
Basic accuracy:
– Open-circuit
Input current < 3.6 mA,
adjustable in the works
between 1 and 4 mA
– Short-circuit
input current > 21 mA
adjustable in the works
between 20 and 23 mA
– Output signal
linear response
For an open-circuit output
0 mA (with 4...20 mA)
– 5 mA (with 0...20 mA)
For a short-circuit
output approx. 26 mA
– Increasing output signal
Output approx. 115% of full-
scale value, e.g 23 mA for
output 0/4...20 mA or
11.5 V for output 0/2...10 V
– Decreasing output signal
(only possible for live zero)
Output approx. 10% of full-
scale value, e.g. 2 mA for
output 4...20 mA
or 1 V for output 2...10 V
Failure signalled by red LED
1 relay, 1 potentially-free change-
over contact (see Table 2)
Contact rating
AC: ≤ 2 A / 250 V
(500 VA)
DC: ≤ 1 A / 0.1...250 V
(30 W)
Adjustable by switch
– Relay "energized" or
"de-energized" in the case
of a failure
Limit error ≤ ± 0.2%
Including linearity and reprodu-
cibility errors
Reference conditions:
Ambient temperature
Power supply
Output burden
Influencing factors:
Temperature
Burden influence
Long-time drift
Switch-on drift
Common and transverse
mode influence
Output + or –
connected to ground:
Regulations
Electromagnetic
compatibility:
Intrinsically safe:
Electrical standards:
Protection (acc. to IEC 529
resp. EN 60 529):
Operating voltage:
Contamination level:
Overvoltage category
acc. to IEC 664:
Double insulation:
Test voltage:
23 °C, ± 2 K
24 V DC ± 10% and
230 V AC ± 10%
Current: 0.5 · R
max.
ext
Voltage: 2 · R
min.
ext
< ± 0.1% per 10 K
< ± 0.1% with current output
< 0.2% with voltage output,
if R
> 2 · R
min.
ext
ext
< ± 0.3% / 12 months
< ± 0.2%
< ± 0.2%
< ± 0.2%
The standards DIN EN 50 081-2
and DIN EN 50 082-2 are obser-
ved
Acc. to DIN EN 50 020:
1996-04
Acc. to IEC 1010 resp.
EN 61 010
IP 00
< 300 V between all insulated
circuits
2
III for power supply
II for measuring input, measuring
output and output contact
– Power supply versus all
circuits
– Measuring input versus
measuring output and
output contact
– Measuring output versus
output contact
– Front plate versus all circuits
Power supply versus measuring
input, measuring output and
output contact 3.7 kV, 50 Hz,
1 min.
Measuring input versus meas-
uring output 2.3 kV, 50 Hz,
1 min.
Measuring output versus output
contact 2.3 kV, 50 Hz, 1 min.
Frontplate versus all circuits
2.3 kV, 50 Hz, 1 min