SLAVE MODE

Starting from the main display, press MENU to go to the main menu. Using UP and DOWN, now select the Slave menu option and press
ENTER to confirm your selection. Use a DMX cable to connect the slave and the master unit (same model, same software version),
and activate the static stand-alone mode and the timer function on the master unit if desired. The slave unit will now follow the master
unit precisely.
SYSTEM SETTINGS (Settings)
Starting from the main display, press MENU to go to the main menu. Using UP and DOWN, now select the "Settings" menu option and press
ENTER to confirm your selection.
This will take you to the submenu for setting the submenu options (see table, use UP and DOWN to select, press ENTER to confirm, use UP
and DOWN to change status/value, press ENTER to confirm):
Settings (bold = factory setting)
Display Reverse
=
Rotate display
Display Back-
=
Display Backlight
light
DMX Fail
=
Operating status if DMX
signal is lost
Dimmer Curve
=
Dimmer curve
Dimmer
=
Dimmer response
Response
PWM Frequency
=
Sets the LED PWM
frequency
Autolock
=
Automatically locks the
control elements
Calibration
=
Sets the maximum
brightness
On
Display rotates 180° (e.g., for overhead installation)
Off
Display does not rotate
On
Permanently on
Off
Deactivation after approx. 1 minute of inactivity
Hold
Last command is held
Blackout
Activates Blackout
Linear
Light intensity increases linearly with DMX value
Exponential
Light intensity can be finely adjusted at lower DMX values
and broadly adjusted at higher DMX values
Logarithmic
Light intensity can be broadly adjusted at lower DMX values
and finely adjusted at higher DMX values
S-curve
Light intensity can be finely adjusted at lower and higher
DMX values, and broadly adjusted at medium DMX values
LED
The spotlight responds abruptly to changes in the DMX
value
Halogen
The spotlight behaves like a halogen spotlight with soft
changes in brightness
800 Hz / 1200 Hz /
2000 Hz / 3600 Hz /
12 kHz / 25 kHz
On
Automatically locks the control element after approx. 30
seconds of inactivity. Display shows: "LOCKED"
Unlock: Press UP and DOWN at the same time for approx.
5 seconds
Off
Deactivates automatic locking of the control elements
White
Cross-mode brightness configuration, with values from 000
to 255
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

H2 tClh2dClh2dwhClh2tClh2twh

Table des Matières