Starting the LPG boiler
1.
Open the regulator and service tap for the LPG.
2.
Turn the thermostat knob to ignition position (see
fig 2). The indicator light for the ignition spark starts
flashing.
3.
Press the thermostat knob down as far as it will go.
Hold it down for about 15 seconds after the indica-
tor light has gone out. (The boiler has ignited as
soon as the warning light goes out, but in order
for the ignition safety cut-out to remain open, the
thermostat knob must be held down for the neces-
sary period).
4.
Release the thermostat knob.
5.
Turn it to operating position and set the desired
temperature (see chpt 2:4).
6.
If the indicator light starts flashing immediately after
the thermostat knob has been released the boiler
has not ignited. Press the thermostat knob down
again and repeat the starting procedure as above,
but hold it down a little longer.
7.
You can also check through the window in the lower
front plate whether the boiler is lit.
Should the boiler go out, turn the thermostat knob to
stop position (see fig 3). wait 3 minutes and repeat
the starting procedure.
The boiler is equipped with automatic reignition, which
means that if it goes out for some reason, it attempts
to restart for about 20 seconds (until the safety cut-out
has cut the gas supply). Should the gas run out while
the boiler is in operation, the warning light will start
flashing and continue on until the boiler is shut down or
restarted.
2:3
Shutting down the LPG boiler
1.
Turn the thermostat knob clockwise to stop position
(see fig 3). After about 20 seconds, a click should
be heard from the gas valve, which means that the
safety cut-out has closed.
2.
Stop the circulation pump on the control panel.
3.
Close the service tap for the LPG.
NB. When the boiler has gone out, it must not be
reignited until 3 minutes have elapsed.
2:4
Setting for maximum comfort
For maximum comfort and economy, it is important to
set the right water temperature in the system. At low
outside temperatures, a higher water temperature is
required than at more normal temperatures. The ideal
setting on the thermostat knob is when the circulation
pump runs about 75% of the time.
When heating a very cold boiler, the thermostat knob
should not be set to maximum temperature imediately,
but at an intermediate position for the first 10 minutes.
The various figures on the thermostat knob represent
the number of degrees of the water temperature in the
boiler as per fig 4.
When it is extremely cold, the gas boiler and the
immersion heater can be run at the same time. This
means that maximum power is obtained from the heat-
ing system. When the heating system is used at a high
altitude, the boiling point of the liquid mixture changes.
14
In this case the system temperature should be lowered
as per fig 5.
In order to utilize the principle of water-born heat in the
best possible way, it is important that air can pass free-
ly under beds and behind back cushions. If the vehicle
has a fitted carpet, for example, ensure that the carpet
does not cover the intake hole for the convectors. It is
equally important that the cushions and blankets do
not prevent air circulation behind the back cushions.
2:5
Setting the room temperature
The temperature required inside the vehicle should
be set on the knob of the room thermostat, which is
graduated between 5 and 30
2:6
Circulation pump
In order to make the heated glycol water circulate,
some form of pump is required. In the expansion ves-
sel of the LPG boiler a 12-volt circulation pump is fitted
as standard. The boiler can also be equipped with an
immersion heater with a 240-volt circulation pump. The
choice of which pump to use, and whether it is to run
constantly or be interrupted by the room thermostat, is
made on the boiler's control panel.
2:7
Electrical heating
If the immersion heater is fitted on the boiler it can
only be used if you have access to 230/240 volts ~.
The power output is 1050 and 2100 watts respectively.
Choice of power is made on the boiler's control panel.
Inside the immersion heater's protective cover, there
are two thermostats. One ensures that the immersion
heater maintains an operating temperature of around
80
C while the other acts as overheating protection,
o
which cuts the current automatically if the immersion
heater boils for some reason. If the overheating protec-
tion triggers, it can be reset by pressing in the overheat
reset button on the side of the immersion heater (see
fig 6A).
Make sure that textiles and other inflammable material
cannot come into contact with the immersion heater.
NB. All electrical work on the immersion heater
must be performed by an authorized person.
3.
ExTErNAL STArT
(applies only if the immersion heater is fitted).
Do you want the vehicle to be heated when you arrive?
If so, your neighbour or the warden can start the heat-
ing without having to enter the vehicle. However, your
boiler must be fitted with an immersion heater and
there must be a battery eliminator (art. no. 2921 520)
connected to the boiler.
How to perform an external start:
1.
Plug the battery eliminator into a 230/240-volt
socket.
2.
Plug the 12-volt contact into the power intake on the
boiler's control panel (see fig 1 J).
3.
Select power and circulation pump on the control
panel.
4.
Switch off the main switch in the vehicle.
5.
Disconnect the 230/240-volt cable from the external
power supply.
C.
°