To ensure this product is correctly installed and used appropriately, we highly advise you to
read this user guide very carefully.
1 . I N T R O D U C T I O N
The X3 EX range consists of high performance UPS units with direct connection to the PC via
a USB port. The UPS is Auto-Regulated to provide balanced output power and offers complete
protection for your servers and their peripherals in the event of power cuts or fluctuations. If
power failure due to power cuts, power surges, or transient over-voltage occurs, the UPS will
very rapidly transfer your computer equipment to an alternative power supply. This will allow
you to make a backup, close your program(s) and shut the system down correctly. In normal
power supply conditions, X3 EX will maintain its battery charge in an on-going way to become
completely transparent during all your operations. In other words, this kind of uninterruptible
multifunctional power supply will simplify your tasks. You will be able to check its operating
status quite easily as well as its charge level using the LCD screen. This high-technology UPS
ensures that your computer equipment has a proper and reliable power supply. The main
features of the X3 EX range are given below.
2 . M A I N C H A R A C T E R I S T I C S
▪ A highly-reliable microprocessor control
▪ Automatic output voltage regulator (AVR)
▪ Built-in USB communication port
▪ Input voltage regulation and standardization
▪ Cold start feature if no power supply
▪ Off-mode charging
▪ Green Power Function for energy saving
▪ Automatic restart during AC power recovery
▪ Compact size, lightweight
▪ Phone / modem or network surge protection (RJ45 connectors)
3 . S A F E T Y I N S T R U C T I O N S
IMPORTANT!
Save this manual properly and read carefully the following instructions before installing the
unit. Do not operate this unit before reading through all safety information and operating
instructions carefully. Installation and Wiring must be performed in accordance with the local
electrical laws and regulations. Installing and connecting UPS system in a way that does not
comply with accepted practices releases Infosec Communication from any liability.
Transportation
1.
Please transport the UPS system only in the original package to protect against shock
and impact.
Preparation and good disposals of the device:
1.
Condensation may occur if the UPS system is moved directly from cold to warm
environment. The UPS system must be absolutely dry before being installed. Please
allow at least two hours for the UPS system to acclimate the environment.
2.
Do not install the UPS system near water or in moist environments.