Troubleshooting - Husqvarna PP 492 Manuel D'utilisation

Masquer les pouces Voir aussi pour PP 492:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Always clean the product at the end of the work day.
Use a heavy duty handheld brush or a large paint
brush.
Error messages - wall saw
If there are errors, an error code (A) and an error
message (B) are shown on the display of the remote
control.
A
F08 TRAVEL MOTOR
OVERLOADED
Please check and/or adjust:
(1) Diamond tool for wear
(2) Feed speed and straightness of cut
(3) Saw carriage
Error code
Error message
"MOTOR OVER-
F01
HEATED"
"POWER PACK
F02
OVERHEATED"
F03
"LOW VOLTAGE"
F04
"HIGH VOLTAGE"
F05
"OVER CUR-
RENT"
"NO HALL-SEN-
F06
SOR LENGTH"
"NO HALL-SEN-
F07
SOR ARM"
967 - 001 - 04.02.2020

Troubleshooting

B
OK
OK
MENU
OK
Possible fault
There is not sufficient water
coolant flow to the saw mo-
tor.
There is not sufficient water
coolant flow to the power
pack unit.
There is low voltage supply
to the power pack unit.
There is high voltage sup-
ply to the power pack unit.
There is current overload to
the saw motor.
There is fault on the HALL-
sensor board for travel
movement.
There is fault on the HALL-
sensor card for depth
movement.
Keep the connectors and pins clean. Clean with a
cloth or brush.
Make sure that the water system is not damaged.
Do the procedure shown on the display or speak to an
approved Husqvarna dealer. Push the "OK" button to
delete the error message.
If you close the error message and it does not show on
the display again, you can continue to operate the
product.
If the error message shows again, refer to
Troubleshooting wall saw on page 15 or speak with an
approved Husqvarna dealer. If necessary, do an update
of the software of the power pack unit.
Troubleshooting wall saw
Possible solution
Do a check that the water coolant flows to the saw
motor. The temperature must be maximum 25 °C
and the water flow must be minimum 3.5 l/minute.
Do a check that the water coolant flows to the pow-
er pack unit. The temperature must be maximum
25°C and the water flow must be minimum 3.5 l/
minute. If the message shows up when the con-
nected product is started, go to the operations
menu "Water coolant" and select "ON". Let the wa-
ter coolant supply the power pack unit for a minute
before you start the power pack unit again.
Examine the voltage during operation. Do a check
that all 3 phases are energized. Do a check that
the products supply cables have sufficient cable
area.
Examine the voltage during operation. This mes-
sage usually shows when the product is supplied
by a generator.
Examine that the power cord is installed correctly
and that it is not damaged.
Speak to your servicing dealer.
Speak to your servicing dealer.
15

Publicité

Table des Matières
loading

Table des Matières