Operating Range; Maintenance And Service; Disposal - Daikin CTX07AXVJU Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Heatpump model
Model : CTX07/09/12
122
114.8
104
NOTICE
Maintenance MUST be done by an authorized
installer or service agent.
We recommend performing maintenance at least
once a year. However, applicable legislation might
require shorter maintenance intervals.
1.
Overview: Maintenance and service
This chapter contains information about:
● The yearly maintenance of the outdoor unit
2.
Maintenance safety precautions
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING
NOTICE: Risk of electrostatic discharge
Before performing any maintenance or service work,
touch a metal part of the unit in order to eliminate
static electricity and to protect the PCB.
NOTICE
Do NOT try to dismantle the system yourself: the dismantling of the system, treatment of the refrigerant, oil and
other parts MUST comply with applicable legislation. Units MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.

OPERATING RANGE

2MX18
COOLING
86
68
50
32
14
50
57.2
68 73.4 82.4 86
INDOOR TEMP (°FWB)

MAINTENANCE AND SERVICE

70
64.4
60
50
41
32
23
14
5
INDOOR TEMP (°FDB)
WARNING
■ Before carrying out any maintenance or repair
activity, ALWAYS switch off the circuit breaker on
the supply panel, remove the fuses or open the
protection devices of the unit.
■ Do NOT touch live parts for 10 minutes after
the power supply is turned off because of high
voltage risk.
■ Please note that some sections of the electric
component box are hot.
■ Make sure you do NOT touch a conductive
section.
■ Do NOT rinse the unit. This may cause electric
shocks or fire.
3.
Checklist for yearly maintenance of the outdoor
unit
Check the following at least once a year:
● Outdoor unit heat exchanger.
The heat exchanger of the outdoor unit can get blocked up
due to dust, dirt, leaves, etc. It is recommended to clean
the heat exchanger yearly. A blocked heat exchanger can
lead to too low pressure or too high pressure leading to
worse performance.

DISPOSAL

1-18
HEATING
50
68
86