Operating the MagicSafe MSG150

To avoid false alarms caused by cooking, using deodorants, heavy smoking and alcohol consump-
tion, the vehicle should be ventilated thoroughly before retiring to bed and then the gas detector
should be switched on.
No. in
fig. 8,
description
page 5
1
Green LED
The green LED flashes for approx. 10 minutes after the gas detector has been
connected to a voltage supply or switched on with the RV-AMP-SW auxiliary
switch. While the LED is flashing, the sensor is brought to the operating
temperature.
When the green LED glows constantly, the gas detector is ready for operation.
2
Orange LED:
The orange LED glows if a fault occurs.
3
Red LED (alarm)
The red LED flashes if an alarm has been triggered.
In addition to this, a siren sounds an alarm signal.
(See also chapter "Alarm" on page 18.)
4
Pushbutton
This pushbutton is a test button and also mutes the system.
Test pushbutton
➤ Press this pushbutton once a month or after extended periods of disuse to
✓ The orange and red LEDs flash and a siren sounds.
Mute switch
➤ Press this pushbutton if you wish to switch off the sound during an alarm.
✓ The red LED continues flashing and a brief signal sounds every 45 seconds.
Switching on the MSG150 as a single device or in combination with the external siren
(ref. no. 9101600008)
➤ Insert the 12/24 Vg plug in a socket or switch on the gas detector with the RV-AMP-SW
auxiliary switch.
✓ An acoustic signal sounds and the green LED (fig. 8 1, page 5) flashes for approx. 10 minutes.
During this time the gas detector conducts a system test and the sensor is brought to operating
temperature.
If an alarm occurs, an acoustic signal sounds over the internal siren and the red LED (fig. 8 3,
page 5) glows. If the external siren is connected, an additional acoustic signal sounds over the
external siren.
➤ To interrupt the internal alarm, press the pushbutton (fig. 8 4, page 5).
EN
check the system is functioning.
Then the system is armed again.