Wall installation

Fit the wall-fixing bracket (fig. 1) in such a way that the
convector unit lies in a horizontal position when in-
stalled. The attachment bracket should be fixed to a
level wall surface. Install it onto the wall using 5.5 mm
max. ∅ screws, making sure that it is facing the right
way.
Note: Use the wall-fixing bracket as a template for
marking the position of the unit and the location
of the drill holes.
Dim.
Dim.
Type
L
B
15/192
340
128
15/194
420
208
15/196
580
178
15/198
740
320
15/199
900
405
Locate the device on the open clips at the bottom, on
the wall-fixing bracket, and push in until the spring-
loaded catches at the top and/or sides engage in the
recesses provided in the rear panel.
To release the spring-loaded catch once it has en-
gaged, push on the upper or lateral clip with a screw-
driver or similar (see fig.1 – item Z and fig.2 – item E).