Electrical Connection; Technical Specifications - EPTA Costan GRANVISTA INTEGRAL WL Instructions Pour L'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
Modello - Modèle - Model
Modell - Modelo - Modelo
Fabbricante - Constructeur - Manufacturer
Hersteller - Fabricante - Fabricante
IMPORTANT: placing fixed panels on the top of the cabinet is advised against, as this
part must be accessible for servicing purposes.
CONDENSATE EVAPORATION PAN OPTION ON WATER-LOOP CABINET: the system is
compatible with a naturally cooled water loop (dry-cooler). In the case of a water loop
with forced cooling at a constant temperature (chiller / liquid cooler), the water tempe-
rature must be set at 25°C minimum in order to allow the evaporation of the conden-
sates. Note that the water temperature can be naturally lower than 25°C in winters due
to outdoor conditions, but must not in this case be over-cooled.

5. ELECTRICAL CONNECTION

IMPORTANT: ahead of the case there must be a MEANS FOR DISCONNECTION FROM
THE SUPPLY MAINS HAVING A CONTACT SEPARATION IN ALL POLES THAT PROVIDE
FULL DISCONNECTION UNDER OVERVOLTAGE CATEGORY III CONDITIONS (see fig.
17). The position of the cut-out switch must enable its actuation in any emergency
situation (maximum distance 3 m). Show the position of the cut-out switch to any pro-
spective operator.
The refrigerator must be installed by professionally qualified personnel, in accordance
with the instructions provided by the manufacturer and local regulations. Incorrect in-
stallation may cause harm to persons, animals and property. The manufacturer assu-
mes no responsibility for such damage.
A supply cable of type HO5VV-F 1mm² or higher must be used for the main supply.
Make sure that the system power supply voltage corresponds to the values appearing
on the rating plate of the equipment. Consider also that the maximum allowable power
voltage variation is +/-6%.
BEFORE CONNECTION, CHECK THAT THE POWER SOURCE IMPEDANCE IS EQUAL TO
OR LOWER THAN 0,383 OHM.
IMPORTANT: THE EQUIPMENT MUST BE PROPERLY EARTHED. The manufacturer as-
sumes no responsibility for any damage resulting from non-observance of this safety
principle. If the cabinet must be installed far from electric power source, make certain
that the connection complies with the standards in force.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
THE MANUFACTURER DISCLAIMS ALL RESPONSIBILITY FOR ANY PERSONAL INJURY
OR PROPERTY DAMAGE ARISING FROM INCORRECT INSTALLATION.

6. TECHNICAL SPECIFICATIONS

The built-in electrical installation is composed of control devices lodged in the lower part
GRANVISTA INTEGRAL WL