Specifications
Sensitivity . . . . . . . . . . . . . . . . . 5 PPM Methane (main component of natural gas)
Power Supply . . . . . . . . . . . . . . . Two "D" cell alkaline batteries (3.2 V @ 125 mA)
Battery Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Approximately 25 hours
Operating Temperature Range. . . . . . . . . . . . . . . . . .-4 to +122° F (-20 to +50° C)
Storage Temperature Range . . . . . . . . . . . . . . . . . . .-4 to +140° F (-20 to +60° C)
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85% RH NC max.
Pollution Degree. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overvoltage Category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Weight (with batteries) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.18 lb (0.53 kg)
Product Warnings
W A R N I N G
To prevent ignition of a hazardous atmosphere, batteries must only
be changed in an area known to be nonhazardous (i.e., completely
free of combustible gas).
W A R N I N G
Use only Duracell
approval.
W A R N I N G
Always check instrument operation with a known combustible leak
source before use.
W A R N I N G
GAS-Mate will detect leaks as described below but may not indicate
when a hazardous atmosphere is present due to its Auto Zeroing
function. Lack of a reading by GAS-Mate should not be taken as an
indication that the atmosphere is totally safe.
W A R N I N G
There are no user serviceable parts inside. Do not disassemble
GAS-Mate.
®
DURACELL
is a registered trademark of Duracell, Inc., Bethel, Connecticut.
®
MN1300 batteries to maintain intrinsically safe
5