EHEIM play 2500 Notice D'utilisation page 20

Masquer les pouces Voir aussi pour play 2500:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
English
3. Use a screwdriver to carefully prise the pump cover ⑤ uniformly to the front out of the motor hous-
ing.
4. Pull the impeller ④ out of the motor housing.
5. Install the pump again in reverse order.
‧ When assembling, make sure that the lugs on the pump cover engage in the recesses in the motor
housing.
‧ Make sure that the impeller is installed complete with the two bearing bushings ③ (⌦F).
‧ When assembling, make sure that the locking ring engages easily when being screwed on.
7.
Clearing faults
ATTENTION! Electrocution!
▶ Before clearing faults, remove the mains plug.
Faults
Pump does not start
Pump does not pump
Pump not pumping
sufficiently
For other faults, please contact EHEIM Service.
8.
Decommissioning
Storing and overwintering
1. Take the appliance out of the pond.
2. Clean the appliance
3. Store the appliance in a frost-proof place.
Store the appliance in a water-filled container to avoid starting difficulties in the spring. The mains plug
must not be submerged.
Possible cause
No mains voltage
Mains plug is not inserted
Impeller is blocked
Thermal cut-out has activated
(except PLAY1000)
Filter housing is soiled
20
Remedy
▶ Check the mains voltage
▶ Check the supply line
▶ Insert the mains plug in the mains
socket
▶ Clean the pump
1. Remove the mains plug and let
the pump cool down.
2. Insert the mains plug again after
approx. 1 hour.
▶ Clean the filter housing

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Play 3500Play 1000Play 1500

Table des Matières