inStaLLatiOn

Safety

inStaLLatiOn
6.
safety
Only qualified contractors should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1

general safety instructions

We can only guarantee trouble-free function and operational re-
liability if original spare parts intended for the appliance are used.
6.2

instructions, standards and regulations

Note
Observe all applicable national and regional regulations
and instructions.
6.3

water installation

6.3.1 cold water line
Steel or copper pipes or plastic pipework are approved materials.
Damage to the appliance and environment
!
A safety valve is required.
6.3.2 dHw line
Copper, stainless steel or plastic pipework are approved materials.
Damage to the appliance and environment
!
Beim gleichzeitigen Einsatz von Kunststoff-Rohrsystemen
If a flanged immersion heater is fitted and plastic pipe-
work systems are used at the same time, observe the
maximum permissible temperature / the maximum per-
missible pressure in chapter "Specification / Data table".
Damage to the appliance and environment
!
Operate the appliance only with pressure-tested taps and
valves.
16
| SBS 601-1501 W SOL
7.

appliance description

7.1

standard delivery

Delivered with the appliance:
- 2x temperature sensors
- 2x heat conducting paste
- additional type plate
7.2

accessories

Depending on the static pressure, safety assemblies and pressure
reducing valves are available. These type-tested safety assemblies
protect the appliance against unacceptable excess pressure.
Flanged immersion heaters, circulation set and thermal insulation
are available as accessories.
8.

assembly

8.1

installation location

f Ensure the floor has a sufficient load bearing capacity (see
f
chapter "Specification / Data table").
f Ensure the floor is level.
f
f Check the height of the room and of the unit when tilted (see
f
chapter "Specification / Data table").
8.2

transport

The lifting eye can be fitted to the top of the appliance to assist
handling.
8.3
assembly
8.3.1 Fitting the thermal insulation, if appropriate.
f Position the appliance in its intended site.
f
f Fit the thermal insulation according to the instructions sup-
f
plied. For this, ensure that there is enough space for the
installation task. You can then link the appliance into the
heating and DHW system.
8.3.2 installing the manual air vent valve
f Install a manual air vent valve at the air vent valve
f
connection.
WWW.StieBeL-eLtrOn.COM