7.7 – USE
-
To activate the keypad press any key for 3 seconds, then you can view and change the set point, if necessary;
press the
arrow keys by pressing and holding for 3 sec the same key.
-
With the keypad active, a manual defrost can be selected; press and hold for 3 sec the
evaporator temperature is no higher than +8°C, a manual defrost phase is activated. This phase ends either
when the time of 20' has elapsed or when the temperature measured by the evaporator sensor is (+8°C). The
automatic defrost, managed by the controller, takes place once every 12H for a max. of 20' during which time
the readout dEF is shown on the display.
-
With the keypad active, press keys
temperature respectively, which are recorded by the sensor inside the cabinet. The displayed values are
preceded by the readouts LO and HY respectively. To reset this stored value, press and hold for 3sec the
key at the time it is displayed. On the display this reset is preceded by the readout RST (reset).
7.7.1 – SPECIAL USE
-
With the keypad active, press and hold for 3 sec the
This phase lasts (1H) at a temperature (+4°C). These values are factory set in the controller. Unlike the normal
refrigerating phase, in this case the symbol
symbol will go out and the appliance will start once again to operate with the previous set point.
7.7.2 – STOPPING FOR LONG PERIODS
With the appliance OFF and the keypad active, press the
Thoroughly clean the appliance (as described under 8.2) and make sure the door is left ajar at the end of cleaning and
remains ajar for the entire period that the appliance is not used.
WL5/1-2 Rev.00 05-2013
key just once to display the set temperature, which can be changed using the up and down
and
just once to display the maximum and minimum
key to activate the CONTINUOUS CYCLE phase.
on the display is lit. When the set time (1H) has elapsed, the
key and pull the plug out of the socket.
key and if the
pag. 54