Technical Data; Operating Conditions - Burkert 2511 Instructions De Service

Masquer les pouces Voir aussi pour 2511:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4
sysTem descRIpTIOn
4.1 general description
The cable plug booster Type 2511 consist of a polyamide body with
integrated electronics and a connector diagram in accordance with DIN
EN 175301-803 (previously DIN 43650 Form A).
The cable plug is used exclusively to control DC coils. The built-
in rectifier makes it possible to operate with DC or alternating
current.
4.2 function
The cable plug booster Type 2511 is used to increase the power
of solenoid valves. The switchable pressure range can therefore be
extended. Furthermore, the power consumption and the coil temperature,
e.g. during continuous operation, can be reduced considerably. Appro-
priate solenoid coils must be individually designed for the particular valve
and power supply. Please contact your Bürkert sales office.
The high pick-up power is generated by overexcitation. When the valve
is actuated, the electronics drop to a low holding power. The electronics
in the 24 V DC model are able to detect the switching point of the valve
and automatically change to the reduced power phase after switching,
5

TechnIcal daTa

5.1 Operating conditions

Operating temperature
Protection class (IEC 60529)
Contamination level
5.2 conformity
In accordance with the EC Declaration of conformity, the cable plug
booster Type 2511 is compliant with the EC Directives.
5.3 standards
The applied standards, which verify conformity with the EC Directives,
can be found on the EC Type Examination Certificate and / or the EC
Declaration of Conformity.
5.4 mechanical data
Dimensions
See data sheet
(approx. 34 x 34 x 69 mm)
Body material
Polyamide
Body cover
Polysulphone, Ultrason
english
6
Interference resistance
in accordance with EN 61000-4
Interference radiation
in accordance with EN 55011
Assignment identification number for voltage:
Identification
Voltage
number
181 630
24 V AC/DC
138 306
110 - 230 V AC/DC
141 314
with electronics for reduced power
The following data applies to identification number 141 314:
1)
Power supply voltage
12 - 48 V AC/DC for 8 watt coils
Pick-up power
approx. 8 W
Pick-up time
approx. 200 ms
Holding power
< 2 W
Rated voltage
250 V
2)
Rated current
0.73 A
Connection
see Chapter „5.6" as well as terminal strip
-10 ... +55 °C
IP65
3
®
2)
1)
while the overexcitation phase of models operating at a different power
supply voltage is a constant 400 ms.
Furthermore, the voltage signal of the 24 V model is indicated via an LED.
english
Seal
NBR
Contact material
Brass, silver-plated
Attachment
Cheese-head screw M3 x 35 mm
Indicator LED
for 24 V AC/DC only
Connection
3-pin / 2-pin terminal strip in the device
Wire cross-section max. 1.5 mm
Cable diameter 6 - 7 mm
Output
Cable outlet
Can be rotated by 180°
Number of pins
2-pin / 2-pin + Protective conductor
Contact gap
18 mm in acc. with DIN EN 175301-803
5.5 electrical data
Power supply voltage
24 V AC/DC in acc. IEC 364-4-41 (PELV)
1)
Pick-up power
max. 72 W
1)
Pick-up time
1)
max. 400 ms
Holding power
approx. 4 W
1)
Max. duty cycle ED
10/min
Switch point detection
for 24 V DC only
5.6 pin assignment
Valve output
PE
Valve output
PE
Fig. 1:
Pin assignment 110 - 230 V
Valve output
Valve output
Fig. 2:
Pin assignment 24 V
english
Type 2511
5
2
+ − ∼
− + ∼
PE
+ − ∼
− + ∼
7

Publicité

Table des Matières
loading

Table des Matières