Automatic repositioning
If the programmer blocks due to an encoder count error
mer reset
, when one of the motors has been released
problem with one of the motors
flash simultaneously for 2 seconds and will then switch off for 10 seconds.
After the programmer has been in this condition for 3 minutes it will (after pre-
flashing for 10 seconds) automatically move the gate, slowly, to the completely
closed position (2 times as in the programming procedure) in order to recover the
correct position. At this point the programmer will function normally.

DISPLAY MODE

Using the PROG button you can access the following functions in
sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
- display the number of manoeuvres;
The status of the security devices
FTCS
and
CSP
are always shown on the display.
Memorising
the
DIP-SWITCH
displaying the firmware version (e.g. "10")
The segments regarding the command status
(LED "ON"
command active) and safety status
(LED "ON"
safety device at rest) light up.
The number of manoeuvres appears on the
display. This number always remains visible until
you change the setting. Once 999999 has been
exceeded the lighting up of the decimal point on
the display equals 1 million + the six figure
number.
In the test mode (activated when the motor has
stopped) it is possible to check the status of the
command and safety devices. The warning lights
will activate once, each time a "TA-TC-TAL-TD-
TB-FTCI-FTCS-CSP" command is received. In
this
mode
you
can
communication using the external program,
connected to the CSER connection via cable.
While communication is active dashes will appear
on the display; after 5 seconds of inactivity you
will be moved back to the test mode. To return
to the normal mode press the button again "test"
will appear, then wait for 10 seconds.
APL
Setting the limited opening space
e distance of gate 1
PRESS
10 sec
PROG
10 seconds after the last modification
you will be automatically moved out
of the mode and the selected values
will be saved (eg. 4)
Selecting the type of motor
BL1924
Articulated operator arm
BL3924
Articulated operator (integrated)
HL2524
Underground operator
BL224E
Straight arm operator
, after a program-
or there is a
the warning lights and indicator light will
TB
,
FTCI,
PRESS PROG
settings
and
PRESS PROG
PRESS PROG
activate
serial
line
PRESS PROG
:
1
1
1
10 sec
Each time PROG
is
pressed
the
number increases
(from 1 to 4).
PRESS
PROG
To carry out automatic repositioning without waiting for 3 minutes you may send
a (TA, TC, TAL or TD) command to the programmer. If a "TA" command is given
the positioning recovery is carried out in the opening direction.
No commands will be accepted during repositioning but the security devices will
cut in and block all movement if they go into alarm.
press the "PROG" or "TB" button.
test
- set the limited opening distance;
- set the current sensor level;
- selecting the type of motor.
10 sec
10 sec
5 sec
Connect the
programming device
(CSER) and activate it.
PRESS
PROG
Each time PROG
is
pressed
PRESS
number will increase
PROG
(from 1 to 3).
10 sec
PRESS
PROG
PRESS
PROG
21
When the
TA-TC-TD-TAL-TB-FTCI-FTCS, CSP
inputs are activated the warning lights will light up.
PRESS PROG
10 sec
SNS
Setting the current sensor:
10 sec
the
PRESS PROG
10 s after the last modification you will
automatically exit the mode and the
selected values will be saved (eg. 3)
10 sec
10 sec
3 minutes,
10 sec