8
Wiring of the standard device
Control terminals
Analog inputs, analog outputs
Terminal X3
SSP94000X3
Terminal data
Flexible
With wire end
ferrule
)
Note!
The "StateLine" design provides a modified version of this connection.
Terminal X3
SSP94SL0X3
72
Labelling
Description
GA
GND analog signals
AO1
Analog output 1
AO2
Analog output 2
A1+
Analog input 1 +
A1−
Analog input 1 −
A1−
Analog input 1 −
A1R
Terminating resistor for ±20mA
A2+
Analog input 2 +
A2−
Analog input 2 −
"
Shield connection: Fix the shield with EMC wire clamp.
Conductor cross−section
2
[mm
]
0.2 ... 2.5
Labelling
Description
GA
GND analog signals
A1+
Analog input 1 +
A1−
Analog input 1 −
A1−
Analog input 1 −
A1R
Terminating resistor for ±20mA
"
Shield connection: Fix the shield with EMC wire clamp.
l
Tightening torque
[AWG]
[Nm]
24 ... 12
Spring terminal
[lb−in]
EDK94AMH24 DE/EN/FR/ES/IT 6.0