Assembly; Assembling/Installing Equipment - Husqvarna PP 480 HF Manuel D'utilisation

Masquer les pouces Voir aussi pour PP 480 HF:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Assembling/Installing equipment

When the machine has been transported to a suitable site, it
should be connected:
Turn the main switch to the "0"-position.
Connect the incoming power cable (380-480 V, 32 A
European connector). Power units equipped with a single
phase socket (230 V) must also have a neutral wire in
order for the socket to work. The power pack functions
even it there is no neutral wire present.
To be able to use full power output, the power unit must be
connected to a 32 A fuse. With a 16 A or 25 A fuse the
power output is lower so as not to overload the fuse. This
is selected when starting up the power unit.

ASSEMBLY

Connect the water hose to the incoming water connector.
The power unit is equipped with an electric water valve,
which is closed when the power pack is activated. When
the power pack is without electricity, the valve is open to
be able to drain water coolant if there is a risk of freezing.
Connect the supplied power lead and water hose from the
power unit to the saw unit.
Connect the remote control using the supplied Canbus
cable. Tighten the cable connector screws by hand.
– 9
English

Publicité

Table des Matières
loading

Table des Matières