BefoRe use

When unpacking, check that the unit is complete and shows no signs of transport
damage.
Read all the information carefully. They contain important advice about how to use
the unit, safety, maintenance and care. Please keep these operating instructions
somewhere safe and pass on to any subsequent owners. We reserve the right to make
design and equipment changes.
fields of aPPlicaTio
For wet and drying suctioning.
Dust class M vacuum cleaners are suited to suction-ing up/off dry non-flammable dust
non-flammable liquids,
wood dust and hazardous dust with AGW's ≥ 0.1 mg/m
Dust class H vacuum cleaner are suited to suctioning up/off dry non-flammable dust,
carcinogenic and pathogenic particles, non-flammable liquids, wood dust and dusts
hazardous to health with AGW's < 0.1 mg/m
coMMissioning
Switch the unit ON/OFF with the switch ②a in the top section ① (or switch to automatic
mode).
Operating field
Depending on the unit configuration, the following functions and settings are available:
0
= Suction unit >off<
I
= Suction unit >on<
A
= Ready mode for ON/OFF automatic mode.
AC = Ready mode like "A" plus automatic filter cleaning.
The power socket ②b is available for connecting an electrical tool.
Caution! The electrical tool must be switched off during connection. The power socket
is permanently supplied with voltage when the plug is in the mains socket regardless
of the switch setting. In switch setting "0" the power socket could still be used as an
extension cable (e. g. for lights).
8
(Suction unit is switched ON/OFF by the electrical tool)
Filter cleaning function; in this switch setting the vibrator is activated for approx.
10 sec. and then switches off again automatically.
.