Depth Adjustment - Stanley Fatmax Fmfp71928 Manuel D'utilisation Et De Maintenance

Table des Matières
Les langues disponibles

Les langues disponibles

FMFP71928_9R197558RA_18GA BRAD NAILER_MAN_JM_SB1850BN_9R195756RA_FM_SB1850BN_MAN_CC 1/
AIR SUPPLY-PRESSURE AND VOLUME:
Air volume is as important as air pressure. The air volume supplied to the tool may be inadequate because
of undersize fittings and hoses, or from the effects of dirt and water in the system. Restricted air flow will
prevent the tool from receiving an adequate volume of air, even though the pressure reading is high. The
results will be slow operation, misfeeds or reduced driving power. Before evaluating tool problems for these
symptoms, trace the air supply from the tool to the supply source for restrictive connectors, swivel fittings,
low points containing water and anything else that would prevent full volume flow of air to the tool.

DEPTH ADJUSTMENT

Always disconnect air supply: 1. Before making adjustments; 2. When servicing
the tool; 3. When clearing a jam; 4. When tool is not in use; 5. When moving to a
different work area, as accidental actuation may occur, possibly causing injury.
FMFP71928 FASTENER CONTROL ADJUSTMENT
The Fastener Control adjustment feature provides close control of the fastener drive depth; from flush with
the work surface to shallow or deep countersink. First, set the air pressure for consistent drive in the specific
work. Then use the Fastener Control adjustment to give the desired depth of drive.
TO ADJUST FASTENER CONTROL ADJUSTMENT:
1. With air pressure set, drive a few fasteners into a representative material sample to
determine if adjustment is necessary.
2. If adjustment is required, disconnnect air supply.
FMFP71928
Depth Adjustment Knob
-8-