G
AERASGARD
®
ACO
TECHNICAL DATA
Pressure dependence:
Long-term stability:
Gas exchange:
Ambient temperature:
Response time:
Electrical connection:
Enclosure:
Enclosure dimensions:
Cable gland:
Protective tube:
Process connection:
Protection class:
Protection type:
Standards:
Optional:
®
AERASGARD
- SD
2
AERASGARD
®
2
®
AERASGARD
ACO
- W
2
®
AERASGARD
ALQ - CO
2
AERASGARD
®
AFTM - CO
AERASGARD
®
AFTM - LQ - CO
Type ⁄ WG02
2
ACO2-SD-U
ATM - CO
- SD
2
ATM-CO2-SD-U
ACO
-W
2
ACO2-W
ACO2-W-DISPL AY
ALQ - CO
-W
2
ALQ-CO2-W
ALQ-CO2-W-DISPL AY
AFTM - CO
-W
2
AF TM-CO2-W
AF TM-CO2-W-DISPL AY
AFTM - LQ - CO
-W
2
AF TM-LQ-CO2-W
AF TM-LQ-CO2-W DISPLAY
Outputs:
Equipment:
Note:
Accessories
SF-M
Metal sinter filter, Ø 16 mm, L = 32 mm, exchangeable, stainless steel V4A (1.4404)
WS-03
Weather and sun protection hood, 200 x 180 x 150 mm, stainless steel
For further information see last chapter!
- W ⁄ ALQ - CO
- W ⁄ AFTM - CO
2
2
± 0.13 % ⁄ mm Hg
< 2 % in 15 years
by diffusion
-10...+60 °C
< 2 minutes
0.14 - 1.5 mm
2
, via screw terminals
plastic, UV-stabilised, material polyamide, 30 % glass-globe reinforced,
with quick-locking screws (slotted ⁄ Phillips head combination),
colour traffic white (similar to RAL 9016),,enclosure cover for display is transparent!
126 x 90 x 50 mm (Tyr 2)
M 16 x 1.5; including strain relief, exchangeable
stainless steel, Ø 16 mm, NL = 55 mm
by screws
III (according to EN 60 730)
IP 65 (according to EN 60 529)
CE conformity, electromagnetic compatibility according to EN 61 326, EMC Directive 2014 ⁄ 30 ⁄ EU
three-line display with illumination, cutout approx. 70 x 40 mm (W x H),
for displaying actual humidity, actual temperature, air quality and / or the actual CO
2
- SD
On-wall temperature and CO
On-wall CO
2
- W
On-wall air quality (VOC) and CO
- W
2
for humidity, temperature and CO
- W
Multifunctional on-wall sensor
2
for humidity, temperature, CO
Measuring Range
Humidity
Temperature
-
-
-
-35...+80 °C
-
-
-
-
-
-
-
-
0...100 % r.H.
-35...+80 °C
0...100 % r.H.
-35...+80 °C
0...100 % r.H.
-35...+80 °C
0...100 % r.H.
-35...+80 °C
0 -10 V or 4...20 mA (selectable via DIP switches, selected variant applies for all outputs) -
Standard on-wall sensor Ax x - SD with fixed output 0 -10 V!
W = changeover contact - Standard on-wall sensor Ax x - SD without changeover contact !
This unit must not be used as safety-relevant device!
- W ⁄ AFTM - LQ - CO
- W ⁄ ATM - CO
2
2
sensor, Standard
2
sensor, Premium
sensor, Premium
2
content, Deluxe
2
content and air quality (VOC), Deluxe
2
CO
VOC
2
(switchable)
0...2000 ⁄ 5000 ppm
-
(switchable)
0...2000 ⁄ 5000 ppm
-
(switchable)
0...2000 ⁄ 5000 ppm
-
0...2000 ⁄ 5000 ppm
-
(switchable)
0...2000 ⁄ 5000 ppm
0...100 %
0...2000 ⁄ 5000 ppm
0...100 %
(switchable)
0...2000 ⁄ 5000 ppm
-
0...2000 ⁄ 5000 ppm
-
(switchable)
0...2000 ⁄ 5000 ppm
0...100 %
0...2000 ⁄ 5000 ppm
0...100 %
11
- SD ⁄ ACO
- SD
2
2
content
2
Equipment
Item No.
Display
(Baldur 2)
-
1501- 7110-1001- 200
-
1501- 7112-1001- 200
W
1501-7110- 7301- 200
W
■
1501- 7110- 7371-200
W
1501-7111- 7301- 200
W
■
1501- 7111- 7371-200
W
1501- 7116- 7301- 200
W
■
1501- 7116- 7371- 200
W
1501- 7118- 7301- 200
W
■
1501- 7118- 7371- 200
7000- 0050-2200- 100
7100-00 40-6000- 000
Rev. 2018 - V22
(continued)