Télécharger Imprimer la page

Liens rapides

30" ( 76.2 cm) and 36" (91.4 cm) ELECTRIC
Built-in Ceramic Downdraft Cooktop
IMPORTANT:
Read and save these
instructions.
IMPORTANT:
Installer: Leave Installation
Instructions with the homeowner.
Homeowner: Keep Installation
Instructions for future reference.
Save Installation Instructions for local
electrical inspector's use.
Downloaded from
www.Manualslib.com
Installation Instructions
For the way it's made
Write down the model and serial numbers
before installing cooktop.
Both numbers are on the model/serial
rating plate, located on the bottom of the
cooktop.
Model #___________________________
Serial # ___________________________
manuals search engine
®
®
Questions regarding features,
operation, performance, parts or
service? Call 1-800-422-1230 or visit
our web site at www.kitchenaid.com
Part No. 8285364
loading

Sommaire des Matières pour KitchenAid 8285364

  • Page 1 ® ® For the way it’s made Questions regarding features, operation, performance, parts or service? Call 1-800-422-1230 or visit our web site at www.kitchenaid.com IMPORTANT: Read and save these instructions. Write down the model and serial numbers before installing cooktop.
  • Page 2 Before you start... cabinet storage is to be provided, the Your safety and the safety of WARNING: To reduce the risk of fire, risk can be reduced by installing a others is very important. electric shock, or injury to persons, range hood that projects horizontally a observe the following: We have provided many important...
  • Page 3 Product Dimensions Cutout Dimensions 29-1/2" (74.9 cm) - 30" (76.2 cm) cooktop 31-1/2" (80 cm) - 30" (76.2 cm) cooktop 35-1/2" (90.2 cm) - 36" (91.4 cm) cooktop 21-13/16" 37-1/2" (95.3 cm) - 36" (91.4 cm) cooktop cutout width (54.4 cm) width depth 21"...
  • Page 4 Venting system requirements The blower housing is set to vent Venting system must terminate to the Do Not exhaust more than one outside. straight out the back from the cooktop. To downdraft cooktop into a single vent vent down, left or right, see “Installation,” system.
  • Page 5 Determine equivalent length of vent. Maximum 6" (15.2 cm) round metal vent equivalent length of vent is 60 ft (18.3 m). 6" (15.2 cm) transition round PVC wall 6" (15.2 cm) List the number of each piece and length of straight vent you will use. sewer pipe round metal vent Multiply the equivalent length by the number of pieces.
  • Page 6 The downdraft cooktop must be Locate the junction box to allow as Electrical connected to the proper electrical voltage much slack as possible between the requirements junction box and cooktop so that the and frequency as specified on the downdraft cooktop can be moved if model/serial rating plate.
  • Page 7 Tighten screws on conduit connector. You have just finished installing your 4. Connect the two black wires together with new KitchenAid downdraft cooktop. Turn on electrical supply. twist-on connectors. To get the most efficient use from 5. Connect the two red wires together with your new cooktop, read your Use &...
  • Page 8 Part No. 8285364 ® © 2002 KitchenAid. ® Registered Trademark/Trademark of KitchenAid U.S.A., KitchenAid Canada licensee in Canada Prepared by KitchenAid, Benton Harbor, Michigan 49022 Printed in U.S.A. Downloaded from www.Manualslib.com manuals search engine...
  • Page 9 Conserver les instructions d’installation à N ° de modèle l’intention de l’inspecteur local des installations électriques. N ° de série N ° de pièce 8285364 Downloaded from www.Manualslib.com manuals search engine...
  • Page 10 Avant de commencer... en conformité avec les prescriptions On devrait éviter d‚installer un placard Votre sécurité et celle des autres du Code national des installations de rangement au-dessus des unités de est très importante. électriques ANSI/NFPA 70 - dernière surface afin d‚éliminer le risque édition*, ou des normes ACNOR Nous donnons de nombreux d‚incendie ou de brûlures lorsqu‚on...
  • Page 11 Dimensions du produit Dimensions de l’ouverture à découper largeur de 80 cm (31 1/2 po) - table de cuisson de 76,2 cm (30 po) 74,9 cm(29 1/2 po) - table de cuisson de 76,2 cm (30 po) profondeur largeur de 95,3 cm (37 1/2 po) - table de 90,2 cm (35 1/2 po) - table de cuisson de 91,4 cm (36 po) 54,4 cm cuisson de 91,4 cm (36 po)
  • Page 12 Prescriptions concernant le système d’évacuation Le système doit décharger l’air à bas, vers la gauche ou vers la droite, voir La longueur du conduit et le nombre l’extérieur. “Installation”, page 6. de coudes devraient être maintenus au minimum pour une performance Ne pas terminer le conduit d’évacuation La longueur nominale d’un conduit efficace.
  • Page 13 conduit métallique diam. 15,2 cm (6 po) raccord de Déterminer la longueur équivalente du conduit transition tuyau PVC/ d’évacuation. La longueur équivalente maximale du bouche de égout diam. conduit métallique décharge conduit d’évacuation est de 18,3 m (60 pi). 15,2 cm (6 po) diam.
  • Page 14 On recommande l’emploi d’un fusible On doit installer un connecteur de Spécifications ou d’un disjoncteur sur les deux conduit de 12,7 mm (1/2 po) conducteurs. La capacité du fusible ne (homologation U.L.) à la boîte de électriques doit pas dépasser la demande de connexion.
  • Page 15 2. Ôter le couvercle de la boîte de votre nouvelle table de cuisson Rétablir le courant électrique. connexion à l’intérieur du placard. KitchenAid à aspiration vers le 3. Connecter le câble d’alimentation bas. Pour obtenir l’utilisation la électrique de la table de cuisson à la plus efficace de votre nouvelle boîte de jonction en utilisant un...