INSTALLATION INSTRUCTIONS
Step 3 - Installation of the Outdoor
Unit (Cont.)
CAUTION
• Max. Elevation: A max
• Max. Length: B max
• Min. Length: B min
• In case the pipe length B is more than C ft, the
refrigerant should be charged, according to D oz/ft.
Indoor
Unit
Outdoor Unit
A max
Outdoor Unit
(ft)
1H09HN2DAA
1H12HN2CAA
33
1H12HN2DAA
1H18HN2CAA
1H18HN2DAA
50
1H24HN2CAA
1H24HN2DAA
31-5000884 Rev. 2
Outdoor Unit
Indoor
Unit
B max
B min
D (oz/
C (ft)
(ft)
(ft)
ft)
66
10
25
1/5
83
Step 4 - Final Check
Explaining Operation To the End User
• Using the User Manual, explain to the user how
to use the air conditioner/heat pump, (the remote
controller, adding/removing the air filters, placing
or removing the remote controller from the remote
control holder, cleaning methods, precautions for
operation, etc.)
• Review precautions for operation.
• Recommend that the user read the Operating
Instructions carefully.
Check Items for Test Run
No gas leak from linesets?
Are the linesets insulated properly?
Are the connecting wirings of indoor and outdoor
firmly inserted to the terminal block?
Is the connecting wiring of indoor and outdoor
fixed?
Is condensate draining correctly?
Is the ground wire securely connected? Is the
indoor unit securely fixed?
Is power source voltage correct according to local
code?
Is there any odd noise?
Does the cooling temperature drop between
20-30°F?
Does the heating temperature raise between
35-40°F?
Is the room temperature display accurate?
21