Télécharger Imprimer la page

Chamberlain RP1EV Manuel D'instructions page 9

Les langues disponibles

Les langues disponibles

LA250EVK, LA300EVK, SL400/600/1000EVK, CB324: CONNECTION
CABLE ENTRY
Run the wire back to the operator control CB324. Ensure the
cable does not interfere with the door movement or hardware.
CONNECTION
The RP1EV is supplied with a 2m cable.
As this product is polarity sensitive, ensure the Brown
wire is terminated into terminal "IR 1,2 or 3", and the Blue
wire is terminated into terminal number "GND".
CB324: CONFIGURATION
Down Direction Only - no configuration
CB324: COMMISSIONING
Auto-commissioning
+
+
+
WARNING
Electrical
TO REMOVE AND ERASE MONITORED ENTRAPMENT
PROTECTION DEVICES
1.
Remove the BBU connector and power down the operator/
CB324.
2.
Remove the RP1EV photo eyes from the CB324 terminals
3.
Power the operator up for three seconds.
4.
Remove power for three seconds.
5.
Repeat three times, leaving power on the third time.
24VDC SYNC
+
BAT-
BAT+
+
9
STBY
UART
LIMI T - SW
CTRL GND 12V
- TX RX 5VO
P -
CL
-
+
SP
EN