LM750EVGB-1: CONNECTION
LM750EVGB-1: CONNECTION
Only one set of RP1EV's can be connected to the LM750EVGB-1.
CABLE ENTRY
Remove the rubber cable gland and make two small holes at
position 2 and 3. Pass the Blue cable through hole 2 and the Brown
cable through hole 3.
CONNECTION
The RP1EV is supplied with a 2m cable.
Use a small screwdriver or pen to hold down the spring terminals,
insert the Brown wire into the grey terminal, then terminate the Blue
wire into the white terminal.
LM750EVGB-1: CONFIGURATION
Down Direction Only - no configuration
LM750EVGB-1: COMMISSIONING
Auto-commissioning
TO REMOVE AND ERASE RP1EV PHOTO EYES DEVICE
1.
Disconnect power supply from the operator
2.
remove RP1EV photo eyes from the operator connection
3.
Power the operator up for three seconds.
4.
Remove power for three seconds.
5.
Repeat three times, leaving power on the third time.
INSTALLATION
WARNING
Electrical
4 3 2 1
DN UP
DN
8
1 1
2 2
3 3
UP P P
S S
BROWN
4
3
EN
BLUE
2
1