c)
Hang the micro-inverter on the screw (as shown on the right) and tighten the screws. Silver cover for
micro inverters should face the panel.
2. AC cable connection method of micro-inverter
a)
Connect the AC three-way handshake cable as shown on the right to make two micro-inverters. The
AC terminals are connected to form a continuous AC branch circuit.
b)
Connect the three-way handshake of the last micro-inverter in the AC branch circuit. Tighten the AC
end cap on the connection cable.
3. Install the cable
AC three-way Handshake Cable Diagram
a)
Components of AC three-way handshake cable:
M16 male (cable size 3*0.75mm²)
M25 female head (cable specification 3*4mm²)
M25 male head (cable specification 3*4mm²)
b)
Connect the M25 female end of the tee connector with the M25 male end of another tee connector
to complete the circuit.
EN