Wiring
Wiring diagram
:
Terminal strip
:
Connector
:
Connec ion
BLK
:
Black
BLU
:
Blue
BRN
:
Brown
GRN
:
Green
Notes
:
Refer to the nameplate for power requirements.
:
IN CASE OF COOLING ONLY TYPE
:
INDOOR
:
OUTDOOR
:
CONDENSER
:
DISCHARGE
:
DRAIN PAN HEATER
Wiring diagram parts table
C5,C6,C119 ........... Capacitor
DB1,DB2,DB3........ Diode bridge
E1H........................ Heater
FU1,FU2,FU3,
FU4,FU5 ................ Fuse
FU6 ........................ Field fuse
IPM1,IPM2 ............. Intelligent power module
L............................. Live
L1........................... Coil
L1R ........................ Reactor
M1C ....................... Compressor motor
M1F........................ Fan motor
MRCW,MR30,
MRM10,MRM20..... Magnetic relay
N ............................ Neutral
Q1L ........................ Overload protector
English
:
Field wiring
:
Relay connector
:
Terminal
ORG
:
Orange
RED
:
Red
WHT
:
White
YLW
:
Yellow
In case of cooling only type
Indoor
Outdoor
Condenser
Discharge
Drain pan heater
PCB1,PCB2,
PCB3......................Printed circuit board
S10,S11,S20,S40,
S50,S70,S80,S90,
S100,S110,HL3,
HN3,X11A,X12A..... Connector
R1T,R2T,R3T ......... Thermistor
S1T ........................Thermostat
SA1 ........................Surge arrester
Q1DI.......................Earth leak detector
SW1 .......................Forced operation switch
V1,V2,V3................Varistor
X1M........................Terminal strip
Y1E ........................Electronic expansion valve coil
Y1R ........................Reversing solenoid valve coil
Z1C,Z2C,Z3C......... Ferrite core
........................Protective earth
https://manual-hub.com/