CBE PRS300 Instructions D'emploi page 6

Masquer les pouces Voir aussi pour PRS300:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PRS300
OVERVIEW
The PRS300 charge regulator can automatically charge the following 12V
using the correct charge line (which can be selected with the switch placed inside the
regulator): lead-gel, lead-acid, AGM and lithium batteries (with integrated electronics).
The charging procedure occurs in three steps:
Step 1:
Battery charge
charge voltage is reached.
NOTE: the end-of-charge voltage is reached only if the batteries are efficient.
Step 2:
Battery charge completion
reduction
.
Maintenance
Step 3:
The cycle starts again when the battery voltage is lower than 13Vd.c., such as in the case of
equipment turning on.
Note:
an uneven exposure to sunlight may lead to varying charging times.
A desulfation function is automatically activated when required by the battery.
Position the selector on the end of charge voltage recommended by the battery
manufacturer.
Generally, the selector should be set on position "A" for lead-acid batteries, position "B" for
lead-gel batteries, and position "C" for AGM and lithium batteries.
STEP 1 - END-OF-CHARGE VOLTAGE
STEP
2 -
CHARGING COMPLETION
STEP 3 - MAINTENANCE VOLTAGE
OPERATING INSTRUCTIONS AND INSTALLATION
- The device shall be used for the regulation of 12V photovoltaic modules charging only.
Connection to other equipment which can damage its correct operation may result in
warranty void.
- The regulator must be exclusively used with the types of batteries listed above. The kind of
battery to charge shall be set on the solar regulator internal board using the apposite
selector (see page 8); the wrong setting of the battery to charge may damage the battery
itself!
Note
: the PRS300 regulator is not suitable for the charging of nickel/cadmium batteries,
lithium batteries without integrated electronics or other kinds of rechargeable or non
rechargeable batteries.
- The regulator is not suitable for external use.
- Install the regulator in an appropriate dry and ventilated housing; make sure there is a
minimum distance of 300mm from the front and 100mm from the sides of the device to the
surrounding surfaces.
- Do not cover the air intakes on the lid.
- The device produces heat during its normal operation. Make sure that the installation of other
equipment near the instrument does not hamper the correct air flow and prevent the
necessary instrument cooling.
- Use cables with an appropriate section (a 6mm²
recommended
).
- Protect the cables from any possible damage.
with the maximum current of the photovoltaic module, until the end of
at the end-of-charge voltage with
at a constant voltage.
TIME
Position "A"
Position "B"
14,1 V
14,3 V
1h
13.5 V
13.8 V
section
for
each
d.c.
battery types
a gradual current
Position "C"
14,7 V
4h
2h
13.8 V
photovoltaic module
- -
GB
GB
is
6

Publicité

Table des Matières
loading

Table des Matières