ENG
• Storage upon power failure
In case of power failure, the instant working state will be locked and maintained till re-electrification.
• Fault indication
The following warnings appearing on the display indicate corresponding faults of the refrigerator.
Though the refrigerator may still have cold storage function with the following faults, the user shall
contact a maintenance specialist for maintenance, so as to ensure optimized operation of the
appliance.
Fault
code
Temperature sensor failure of
E1
refrigerating chamber
Temperature sensor failure of freezing
E2
chamber
Temperature sensor failure of variable
E3
temperature chamber
INSTALLATION INSTRUCTIONS
For refrigerating appliances with climate class
Depending on the climate class, this refrigerating appliance is intended to be
used at ambient temperature ranges as specified following table.
The climate class can be found on the rating plate. The product may not operate properly at temperatures
outside of the specified range.
You can find the climate class on the label inside your refrigerator.
Effective temperature range
The refrigerator is designed to operate normally in the temperature range specified by its class rating.
Class
Extended temperate
Temperate
Subtropical
Tropical
NOTE
The cooling performance and power consumption of the refrigerator may be affected by the ambient
temperature, the door-opening frequency, and the location of the refrigerator. We recommend adjusting
the temperature settings as appropriate.
How to store for best preservation (applicable models only)
Cover foods to retain moisture and prevent them from picking up odors from other foods. A large pot of
food like soup or stew should be divided into small portions and put in shallow containers before being
refrigerated. A large cut of meat or whole poultry should be divided into smaller pieces or placed in
shallow containers before being refrigerated.
Fault description
Ambient temperature range °C
Symbol
IEC 62552 (ISO 15502)
SN
+ 10 to + 32
N
+ 16 to + 32
ST
+ 16 to + 38
T
+ 16 to + 43
Fault
code
Freezing defrost sensor detection
E5
circuit error
E6
Communication error
Circulation of temperature detection
E7
circuit error
EH
Moisture sensor error
ISO 8561
+ 10 to + 32
+ 16 to + 32
+ 18 to + 38
+ 18 to + 43
9
Fault description