Cleaning The Impeller; Technical Data; Service Department - Powerplus Powew67904 Mode D'emploi

Table des Matières
Important ! Note!
Remove the mains plug before all maintenance work.
When the pump is often transported in the course of operation, it should be cleaned out
with clear water after every use.
In case of stationary installation, the function of the bating switch should be checked every
3 months.
All fibrous particles which may have built-up inside the pump housing should be removed
with a water jet.
Every 3 months the shaft ground and as should be cleaned from mud.
Remove deposits on the floater with clear water.
9.2

Cleaning the impeller

If excessive deposits collect in the pump case you must dismantle the bottom part of the pump
as follows:
1.
Remove the intake cage from the pump case.
2.
Clean the impeller with clear water.
Important! Do not put down or rest the pump on the impeller!
3.
Re-assemble in reverse order

10 TECHNICAL DATA

type
Voltage / frequency
Power input
Delivery rate max..
Delivery height max
Immersion depth max.
Water temperature max.
For clean/dirty water:
Housing (plastic(P) / Stainless Steel (SS) )
Water inlet (plastic / Stainless Steel (SS) )
Weight

11 SERVICE DEPARTMENT

Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).
Copyright 2024 VARO NV
POWEW67904
P a g e
| 5
POWEW67904
230V / 50Hz
400W
7500 l/h
5 m
max.7 m
35° C
Dirty
P
P
3.46kg
www.varo.com
EN
Table des Matières
loading

Table des Matières