4.4 Winterization

If there is any danger of frost or freezing conditions then it is advisable to drain down the Largo or Punto jet assembly. To do this
close the suction-sided ball valve and remove the screw plug at the lower part of the pump housing.
After water has drained off, do not re-assemble the screw plug.
The pressure-sided ball valve can remain open.

4.5 Re-operation

Fill the pool up to its normal level. Replace the screw plug into the lower part of the pump housing. Before starting the pump,
rotate the pump manually several times (Turn the ventilating fan clockwise by means of a screw driver) and re-open the ball
valve
5

SERVICE

Only operate the unit if it is in perfect condition. Take care to have it regularly checked and serviced. After
repair or when the unit is brought back into operation, ensure that it has not been tampered with.
The unit must only be serviced by authorized persons. Do not carry out any work which might have
impair the safety of the unit. Only buy original spares from your dealer or uwe.
9
LARGO
1
Ø 48
max. 50
240
(300)
dimensions in cm
450
Ø 90
ca. 930
will not be
delivered
13
450
control panel
approx 5-10 cm
above waterlevel
protection tube
wall duct
gasket
5
2
3
4
min 1000
pump

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Punto

Table des Matières