e. Press the MODE button again. If you wish to deactivate the DCF reception, press the +1
button. "DCF enable" disappears.
f. Press MODE button again to return to normal mode.
• If no DCF reception symbol is displayed, manual clock setting is possible at any time. Follow
the steps a. to f. when the display shows the time (switch to B or C position).
• The device will automatically quit the setting mode if no button is pressed for 15 seconds.
• Once the DCF time signal is successfully received and the DCF reception is activated (DCF
enable is displayed), the manually set time is overwritten.
5.3 °C/°F display change
• When the display shows the current temperature, press +1 button to change between °C or
°F as temperature unit. The time will change from 24 to 12-hour system at the same time.
• In the 12-HR system AM (before noon) or PM (after noon) appears on the display.
5.4 Display mode selection
• Switch position A: Current temperature (display: >)
• Switch position B: Current temperature and time alternately (display: >>)
• Switch position C: Current temperature, highest/lowest temperature and time alternately
(display: >>>)
5.5 Maximum and minimum temperatures
• The maximum and minimum values are automatically reset: The maximum temperature at
8:00 and minimum temperature at 20:00 o'clock. To use this function, the actual time must
be received via DCF or set manually.
• Auto Reset flashes on the display.

5.6 Temperature probe

• The silver pin is the temperature probe. Please take care of it and do not break it. The tem-
perature probe has no adjusting function. It only measures the temperature.
5.7 Backlight and fixing
• The supplied battery will be recharged in an environmentally friendly manner by the solar
panel.
16
27.02.2021
11:07 Uhr
Seite 9
AVENUE PLUS – Digital garden thermometer with solar lighting
• Please consider when choosing a location that the solar panel needs at least 8-10 hours of
light per day to guarantee a long-term sufficient power supply. Attention: Direct sunshine
falsifies the measurement. The thermometer is provided with a light sensor to turn on the
light automatically at dark between 5 and 9 o'clock and 18 and 23 o'clock. Avoid the close-
ness of artificial light (like: street lighting).
• With the ECO slide it is possible to turn the time-controlled illumination on (left) or off (right).
• If the ECO mode is not active the illumination will turn on automatically as soon as the light
sensor indicates darkness.
• When the battery symbol appears on the display, the voltage of the rechargeable battery is
low and the backlight function can be temporarily disabled, until the power supply by the
solar panel is sufficient again.
• Press the plate firmly into the ground.
• Mount the rod and put it into the ground passing through the hole in the middle of the plate.
Fix the thermometer on the rod and turn the solar panel (rotatable 180°) to the direction
where it receives the highest light supply.
6. Care and maintenance
• For best function keep the solar panel always clean. Clean it with a soft cloth and maybe a lit-
tle glass- or display cleaner. Do not use solvents or scouring agents.
• Remove the battery if you do not use the product for a long period of time.

6.1 Battery replacement

• Please change the 1.5 V AA battery when the display becomes weak.
• Use alkaline batteries only. Observe correct polarity.
7. Troubleshooting
Problem
Solutions
➜ Ensure correct polarity, when inserting the battery
No indication
➜ Change the battery
Incorrect indication
➜ Make sure that no objects cover the solar panel
No illumination
(see point 5.7)
➜ Press the
No DCF reception
tion manually
➜ Activate DCF reception (see point 5.2e)
button for 6 seconds and start the initializa-
17