Heating Menu; Cooling Menu - ECOFOREST ecoGEO Série Manuel D'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

XXXXXX scheduler
Day: Monday
: :
OFF
: 8:
ON
3: :
OFF
4: :
ON
opy to:
ALL
XXXXXX tariff
Peak Valley
DHW:
-
Heating:
-5
ooling:
Pool:
-5

3.11. HEATING Menu

3/8
Heating
Enable:
StopT:

3/8
Heating
Enable:
StopT:
Heating buffer
SetT:
DTstart:
Heating groups
-  +
DG:
SG:
5
SG3:
SG4:
oom terminals
SetT

DG:

SG:

SG3:

SG4:

Auxiliary heating X
Emergency:
Support:

3.12. COOLING Menu

User menu
4/8
Heating
ooling
DHW/Legionella prot
Peak / valley tariff for Winter / summer
This allows programming up to 4 time periods for each day of the week.
Independent time schedules can be set up for winter peak, winter valley, summer peak and
summer valley tariffs.
Temperature differential for winter / summer tariff
This allows configure the temperature differentials on the heat pump setpoint in the peak
and valley periods for each service in winter / summer period.
 
5 
- 
5 
Heating
This enables the HEATING mode and adjusts the heating cut-off temperature. The HEATING

mode is never activated for temperatures over the cut-off setpoint.
The
icon indicates that there is a time schedule activated in the HEATING mode.
Heating buffer
This shows the setpoint temperature of the buffer storage tank and allows adjustments to
5
5
be made to the start-up temperature differential.
Heating groups
-  +
This can be used to adjust the heating target outlet temperatures programmed by the
technical service. Each ramp increases or decreased the outlet temperature by 2ºC.
Room terminals
DTc

Used to show and adjust the inside environment temperature setpoint (SetT) and the


comfort temperature differential (DTc) of the terminals of each outlet unit.


Auxiliary heating X
This is used to enable the auxiliary heating system in both EMERGENCY and SUPPORT
mode.
In EMERGENCY mode, the auxiliary system is activated automatically when any of the
alarms are active.
In SUPPORT mode, the auxiliary system is activated automatically for normal HEAT
production, as programmed by the technical service.
42