1. Description
The S105A is especially suited
for foam cleaning and disinfection
using tap water in smaller areas.
The unit is suited for use in rooms
with floor drains.
2. Location
The S105A must be placed in a
frost-free room only.
To ease the operation, leave as
much free space as possible
around the unit.
3. Water supply
Water quantity:
25 l/min. / 6.6 USG p.m.
Pressure:
2.5-5 bar / 250-500 kilopas-
cal/36-73 PSI
Max. temperature:
60°C/140°F
Connection:
1/2" or 3/4" external thread
Note: A closing valve must be
mounted directly before the
It must be expected that the foam
quality and the rinsing effect will be
reduced if the requirements to the
water supply are not met.
Taps, mixing batteries etc. may
have a limiting effect on the wa-
ter quantity. If one of these are
placed before the unit and the
water quantity is not sufficient, it is
re commended to replace it with a
ball valve. The replacement should
be carried out by an authorised
plumber.
3.1 Air supply
Max. air supply:
3,5 bar / 350 kilopascal / 50 PSI.
Connection:
¼" external pipe thread.
Please make sure that the pres-
sure of the air supply does not
exceed the pressure of the water
supply.
unit.
4.1
S 105A
4. Mounting
Mount the included shut off valve
for air with regulation and pressure
gauge on the exiting air unit by
means of a Ø6 mm air hose.
It is recommended to mount the
S105A inside the Ecolab Protect
Junior safe storage unit.
7